
Note
Equipment, etc.
•
Max. water pressure at the nozzle: 700 kN/m
2
(7 bar)
i
•
Fan jet nozzle should be used, min. 45° spread
•
Distance from nozzle to encapsulation: min. 0.4
m
•
Flow: max. 20 liters/min
.
Water cleaner
•
Water pressure at nozzle: max. 2,500 kN/m
2
(25
bar)
•
Type of nozzle: fan jet, min. 45° spread
•
Distance from nozzle to encapsulation: min. 0.4
m
•
Water temperature: max. 80° C
Steam cleaner
i
Typical tap water pressure and flow
Cables
Movable cables need to be able to move freely:
•
Remove waste material, such as sand, dust and chips, if it prevents cable
movement.
•
Clean the cables if they have a crusty surface, for example from dry release
agents.
Dos and don'ts!
The section below specifies some special considerations when cleaning the robot.
Always!
•
Always use cleaning equipment as specified above! Any other cleaning
equipment may shorten the life of the robot.
•
Always check that all protective covers are fitted to the robot before cleaning!
Never!
•
Never point the water jet at connectors, joints, sealings, or gaskets!
•
Never use compressed air to clean the robot!
•
Never use solvents that are not approved by ABB to clean the robot!
•
Never spray from a distance closer than 0.4 meters!
•
Never remove any covers or other protective devices before cleaning the
robot!
3HAC044266-001 Revision: -
171
© Copyright 2013 ABB. All rights reserved.
3 Maintenance
3.6.1 Cleaning, robot
Continued
Summary of Contents for DressPack IRB 6700
Page 1: ...ABB Robotics Product manual IRB 6700 ...
Page 8: ...This page is intentionally left blank ...
Page 14: ...This page is intentionally left blank ...
Page 98: ...This page is intentionally left blank ...
Page 172: ...This page is intentionally left blank ...
Page 550: ...This page is intentionally left blank ...
Page 566: ...This page is intentionally left blank ...
Page 573: ......