Parameter groups
Summary of parameter groups
Group
Contents
01 Actual values
Volt, Amps, rpm.
03 Input references
Fieldbus, D2D.
04 Warnings and faults
05 Diagnostics
Run-time-type counters, bridge
temperature.
06 Control and status words
Control status words.
07 System info
Hardware and firmware information.
10 Standard DI, RO
Digital inputs, relay outputs.
11 Standard DIO, FI, FO
12 Standard AI
Analog inputs.
13 Standard AO
Analog outputs.
14 I/O extension module 1
15 I/O extension module 2
16 I/O extension module 3
19 I/O Operation mode
Speed/torque selection.
20 Start/Stop/Direction
Digital input, Main control word
21 Start/Stop mode
Ramp, coast.
22 Speed reference selection
Analog input, fieldbus
23 Speed reference ramp
24 Speed reference conditioning
25 Speed control
26 Torque reference chain
27 Armature current control
28 EMF and field current control
29 12-pulse/Hardparallel
30 Control limits
Drive operation limits.
31 Fault functions and fault levels
External events, tripping level.
32 Supervision
33 Generic timer & counter
Maintenance.
35 Motor thermal protection
Temperature measurement, load
curve definition.
36 Load analyzer
37 User load curve
40 Process PID
42 Shared motion (2nd motor)
44 Mechanical brake control
45 Energy efficiency
46 Monitoring/Scaling settings
Speed supervision settings, signal
filtering and general scaling settings.
Group
Contents
47 Data storage
Data storage parameters that can be
written to and read from using other
parameters’ source and target
settings.
49 Panel port communication
Local time out.
50 Fieldbus adapter (FBA)
Fieldbus communication
configuration.
51 FBA A settings
Fieldbus adapter A.
52 FBA A data in
Data sent to fieldbus adapter A to the
master (e.g. PLC).
53 FBA A data out
Data read from fieldbus.
54 FBA B settings
Fieldbus adapter B.
55 FBA B data in
Data sent to fieldbus.
56 FBA B data out
Data read from fieldbus.
58 Embedded fieldbus
60 DDCS Communication
D2D + DDCS port.
61 D2D and DDCS transmit data
Defines the data sent from the drive
to the DDCS/D2D link.
62 D2D and DDCS receive data
Defines the data sent from the DDCS/
D2D link to the drive.
70 DCSLink Communication
External extension, 12-pulse
74 … 89 Application specific
groups
90 Feedback selection
Analog tacho, encoder ...
91 Encoder module settings
Configuration of the encoder
interface modules.
92 Encoder 1 configuration
FENxx
93 Encoder 2 configuration
FENxx
94 OnBoard speed feedback
configuration
CON-H01 analog tacho and OnBoard
encoder.
95 HW configuration
e.g. Type code
96 System
Language selection; access levels;
macro selection; parameter save and
restore; control board reboot; user
parameter sets; unit selection; data
logger triggering; parameter; user
lock.
99 Motor data
Motor settings, autotuning
Input signals
10.01
DI status
b0
digital
input
DI1
b1
digital
input
DI2
b2
digital
input
DI3
b3
digital
input
DI4
b4
digital
input
DI5
b5
digital
input
DI6
b15
digital
input
DIL
12.11
AI1 actual value
analog input
12.21
AI2 actual value
analog input
Speed control loop
23.03
Speed reference 7
speed reference ramped
90.01
Motor speed for control
speed feedback
Armature current control loop
27.02
Used current reference
27.05
Motor current
actual value
—
Control loops most wanted signals
Optimization of control loop requires comparison of reference and actual values