23
ABB i-bus
®
EIB / KNX
Commissioning
3.2.3.1 Parameter window
“A – Output”
Fig. 16: Parameter window “Channel A – Output”
Send output value
Options:
on request
after a change
cyclically
after a change and cyclically
This parameter is used to define how the
Output value
should be sent.
Option
On request
= Send output value on request
When this option is selected, the “Output value – Channel A” communi-
cation object appears. As soon as a “1” is received at this communication
object, the current output value is sent once to the “Output value –
Channel A” communication object.
Option
After a change
= Send output value after a change
Option
Cyclically
= Send output value cyclically
Option
After a change and cyclically
= Send output value after a change
and cyclically
In the case of the
after a change, cyclically and after a change and cyclically
options, further parameters appear – see next page.
Output value is sent, every
Options:
5 s/10 s/30 s/1 min/5 min/10 min/30 min/1 h/6 h/12 h/24 h
This additional parameter is used to set the interval for cyclical sending.