Availability of d
u/dt filter and common mode filter by drive type
Availability of common mode filter
(CMF)
Availability of d
u/dt filter
Product type
+E208
Ordered separately, see section
ACS880-04F
Additional requirements for explosion-safe (EX) motors
If you use an explosion-safe (EX) motor, obey the rules in the requirements table above.
In addition, consult the motor manufacturer for any further requirements.
Additional requirements for ABB motors of types other than M2_, M3_, M4_, HX_ and
AM_
Use the selection criteria given for non-ABB motors.
Additional requirements for braking applications
When the motor brakes the machinery, the intermediate circuit DC voltage of the drive
increases, the effect being similar to the motor supply voltage increasing by up to
20 percent. Consider this voltage increase when specifying the motor insulation
requirements if the motor will be braking a large part of its operation time.
Example: Motor insulation requirement for a 400 V AC line voltage application must
be selected as if the drive were supplied with 480 V.
Additional requirements for ABB high-output and IP23 motors
The rated output power of high output motors is higher than what is stated for the
particular frame size in EN 50347 (2001).
This table shows the requirements for protecting the motor insulation and bearings
in drive systems for ABB random-wound motor series (for example, M3AA, M3AP and
M3BP).
Requirement for
Nominal AC supply
voltage
ABB d
u/dt and common mode filters, insulated N-end motor
bearings
Motor insulation
system
P
n
≥ 200 kW
100 kW ≤
P
n
<
200 kW
P
n
< 100 kW
P
n
≥ 268 hp
140 hp ≤
P
n
<
268 hp
P
n
< 140 hp
+ N + CMF
+ N
-
Standard
U
n
≤ 500 V
+ d
u/dt + N + CMF
+ d
u/dt + N
+ d
u/dt
Standard
500 V <
U
n
≤ 600 V
or
+ N + CMF
+ N
-
Reinforced
+ d
u/dt + N + CMF
+ d
u/dt + N
+ d
u/dt
Reinforced
600 V <
U
n
≤ 690 V
Additional requirements for non-ABB high-output and IP23 motors
The rated output power of high-output motors is higher than what is stated for the
particular frame size in EN 50347 (2001).
If you plan to use a non-ABB high-output motor or an IP23 motor, consider these
additional requirements for protecting the motor insulation and bearings in drive
systems:
Guidelines for planning the electrical installation 63
Summary of Contents for ACS880-04F-504A-3
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 04F drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 50: ...50 Mechanical installation ...
Page 56: ...56 ...
Page 116: ...116 ...
Page 122: ...4 3 2 122 Maintenance ...
Page 128: ...128 ...
Page 143: ... Package dimensions Package dimensions without IP shroud kit Technical data 143 ...
Page 158: ...158 ...
Page 160: ...Standard configuration IP20 UL Type Open 160 Dimension drawings ...
Page 161: ...Drive module with options E208 and H370 IP20 UL Type Open Dimension drawings 161 ...
Page 162: ...Drive module with options 0B051 E208 0H371 IP00 UL Type Open 162 Dimension drawings ...
Page 163: ...Drive module with options 0B051 E208 0H371 C217 IP00 UL Type Open Dimension drawings 163 ...
Page 164: ...Drive module with options 0B051 0H371 IP00 UL Type Open 164 Dimension drawings ...
Page 165: ...Mounting plate opening 3AXD50000038119 Dimension drawings 165 ...
Page 166: ...3AXD50000038119 166 Dimension drawings ...
Page 167: ...External control unit 3AXD50000011687 Dimension drawings 167 ...
Page 168: ...168 ...