Safety instructions
7
Grounding
These instructions are intended for all who are responsible for the grounding of the
drive.
WARNING!
Ignoring the following instructions can cause physical injury, death,
increased electromagnetic interference and equipment malfunction:
•
Ground the drive, motor and adjoining equipment to ensure personnel safety in
all circumstances, and to reduce electromagnetic emission and pick-up.
•
Make sure that grounding conductors are adequately sized as required by
safety regulations.
•
In a multiple-drive installation, connect each drive separately to protective
earth (PE).
•
ACS800-01, ACS800-11: In European CE compliant installations and in other
installations where EMC emissions must be minimized, make a 360° high
frequency grounding of cable entries in order to suppress electromagnetic
disturbances. In addition, connect the cable shields to protective earth (PE) in
order to meet safety regulations.
ACS800-04 (45 to 560 kW) and ACS800-02 in first environment: make a 360°
high frequency grounding of motor cable entries at the cabinet lead-through.
•
Do not install a drive with EMC filter E202 or +E200 (available for
ACS800-01 and ACS800-11 only) on an ungrounded power system or a high-
resistance-grounded (over 30 ohms) power system.
Note:
•
Power cable shields are suitable for equipment grounding conductors only
when adequately sized to meet safety regulations.
•
As the normal leakage current of the drive is higher than 3.5 mA AC or 10 mA
DC (stated by EN 50178, 5.2.11.1), a fixed protective earth connection is
required.
Summary of Contents for ACS800-11
Page 1: ...ACS800 Hardware Manual ACS800 11 Drives 5 5 to 110 kW ACS800 U11 Drives 7 5 to 125 HP ...
Page 4: ......
Page 12: ...Safety instructions 12 ...
Page 30: ...The ACS800 11 U11 30 ...
Page 36: ...Mechanical installation 36 ...
Page 54: ...Planning the electrical installation 54 ...
Page 74: ...Installation checklist 74 ...
Page 84: ...Operation 84 ...
Page 104: ...Technical data 102 ...
Page 108: ...Dimensional drawings 106 ...
Page 111: ...External 24 V power supply for the RMIO board 109 5 6 7 8 ...
Page 112: ...External 24 V power supply for the RMIO board 110 ...
Page 113: ......