Safety Instructions
vi
ACx = ACS/ACC/ACP ACS/ACC/ACP 604/607 Frequency Converters
Motor Connections
WARNING! Operation is not allowed if the motor nominal voltage is
less than one half of (ACP: 0.4 times) the ACx 600 nominal input
voltage, or the motor nominal current is less than 1/6 of the ACx 600
nominal output current.
As with all frequency converters employing the most modern IGBT
inverter technology, the ACx 600 output comprises – regardless of
output frequency – pulses of approximately 1.35 times the mains
network voltage with a very short rise time.
The voltage of the pulses can be almost double at the motor terminals,
depending on the motor cable properties. This in turn can cause
additional stress to the motor insulation. The motor manufacturer
should be consulted regarding the construction of the motor insulation.
Failure of the motor to fulfil the following requirements may shorten its
life.
Motor Insulation
Requirement
The requirement of motor insulation level in ACx 600 frequency
converter drive is given below.
Motor Type
Nominal Mains Voltage
Motor Insulation Requirement
ABB Motors
(manufactured from
beginning of 1998)
U
N
<
500 V
6WDQGDUGLQVXODWLRQV\VWHP
525 V
<
U
N
≤
690 V
6WDQGDUGLQVXODWLRQDQGGXGWILOWHU
RU
VSHFLDOLQVXODWLRQV\VWHP
5DQGRPZRXQG0RWRUV
U
N
≤
420 V
0RWRULQVXODWLRQV\VWHPPXVWZLWKVWDQG
Ó
LL
= 1300 V.
420 V
<
U
N
≤
500 V
,IPRWRULQVXODWLRQV\VWHPZLWKVWDQGV
Ó
LL
= 1600 V
DQG
µ
VULVHWLPHD
du/dt filter
LVQRWQHHGHG
With a du/dt filter at the output of the
ACx 600,
PRWRULQVXODWLRQV\VWHP
must
ZLWKVWDQGÓ
LL
= 1300 V.
500 V
<
U
N
≤
600 V
0RWRULQVXODWLRQV\VWHPPXVWZLWKVWDQG
Ó
//
9$GXGWILOWHUPXVWEH
XVHGDWWKHRXWSXWRIWKH$&[
600 V
<
U
N
≤
690 V
0RWRULQVXODWLRQV\VWHPPXVWZLWKVWDQG
Ó
LL
= 1800 V. A du/dt filter must be
used
DWWKHRXWSXWRIWKH$&[
.
)RUPZRXQG0RWRUV
U
N
≤
690 V
,IPRWRULQVXODWLRQV\VWHPZLWKVWDQGV
Ó
//
9DQGULVHWLPH
µ
VQR
GXGWILOWHULVQHHGHG
Summary of Contents for ACS 600 MultiDrive
Page 2: ......
Page 4: ......
Page 14: ...Safety Instructions xii ACx ACS ACC ACP ACS ACC ACP 604 607 Frequency Converters...
Page 17: ...6 3 DUGZDUH 0DQXDO Y Appendix B ACx 607 Dimensional Drawings...
Page 18: ...YL 6 3 DUGZDUH 0DQXDO...
Page 22: ...Chapter 1 Introduction 1 4 ACS ACC ACP 604 607 Frequency Converters...
Page 40: ...Chapter 3 Electrical Installation 3 16 ACS ACC ACP 604 607 Frequency Converters...
Page 44: ...Chapter 5 Maintenance 5 2 ACS ACC ACP 604 607 Frequency Converters...
Page 76: ...Appendix B ACx 607 Dimensional Drawings B 2 ACS ACC ACP 607 Frequency Converters...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......