ACS/ACC/ACP 604/607 Frequency Converters
5-1
Chapter 5 – Maintenance
The ACx 600 requires minimum maintenance.
WARNING! All maintenance work described in this chapter should only
be undertaken by a qualified electrician. The
Safety Instructions on the
first pages of this manual must be followed.
Heatsink
The ACx 600 can run into overtemperature Faults if the heatsink is not
clean. In normal environment, the heatsink should be checked and
cleaned annually.
Use compressed air to remove dust from the heatsink. (The airflow
direction must be from bottom to top.) Also, use a vacuum cleaner at
the air outlet to trap the dust. Fan rotation must be prevented in order to
prevent bearing wear.
Fan
The cooling fan lifespan is about 60 000 hours (R7) or 30 000 hours
(R8 and R9). The actual lifespan depends on the frequency converter
usage and ambient temperature.
Fan failure can be predicted by the increasing noise from fan bearings
and the gradual rise in the heatsink temperature in spite of heatsink
cleaning. If the frequency converter is operated in a critical part of a
process, fan replacement is recommended once these symptoms start
appearing.
Capacitors
The ACx 600 intermediate circuit employs several electrolytic
capacitors. Their lifespan is about 100 000 hours. It depends on the
frequency converter loading and the ambient temperature.
Capacitor life can be prolonged by lowering the ambient temperature. It
is not possible to predict capacitor failure.
Capacitor failure is usually followed by a mains fuse failure or a Fault
trip. Contact ABB if capacitor failure is suspected. Replacements are
available from ABB. Do not attempt operation with other than ABB
specified spare parts.
Reforming
Reform (re-age) spare part capacitors once a year according to
ACS 600 Capacitor Reforming Guide (code: 64059629).
Summary of Contents for ACS 600 MultiDrive
Page 2: ......
Page 4: ......
Page 14: ...Safety Instructions xii ACx ACS ACC ACP ACS ACC ACP 604 607 Frequency Converters...
Page 17: ...6 3 DUGZDUH 0DQXDO Y Appendix B ACx 607 Dimensional Drawings...
Page 18: ...YL 6 3 DUGZDUH 0DQXDO...
Page 22: ...Chapter 1 Introduction 1 4 ACS ACC ACP 604 607 Frequency Converters...
Page 40: ...Chapter 3 Electrical Installation 3 16 ACS ACC ACP 604 607 Frequency Converters...
Page 44: ...Chapter 5 Maintenance 5 2 ACS ACC ACP 604 607 Frequency Converters...
Page 76: ...Appendix B ACx 607 Dimensional Drawings B 2 ACS ACC ACP 607 Frequency Converters...
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 93: ......