ACS 300 User’s Manual
7
Chapter 1 - Overview of This Manual
Type Series
Table 1-1 ACS 300 frequency converter types for 50 Hz and
60 Hz supplies. Mains supply 200 to 240 V.
1)
Allowed for one minute every ten minutes at 50
°
C ambient.
2)
The impedance of mains supply affects the input current.
3)
The single underline (_) in the type designation stands for “0” or
“1”.
Type
designation
3)
Frame
Rated input
current
2)
Output current
Maximum
permissible
rated motor
power
P
N
[kW]
Weight
[kg]
1-phase
I
1
[A]
3-phase
I
1
[A]
Rated
current
I
N
[A]
Short-term
overload
current
I
OVER
[A]
1)
ACS 311-1P1-1
R0
6.6
-
3.0
4.5
0.55
3.1
ACS 311-1P6-1
R0
8.9
-
4.3
6.5
0.75
3.1
ACS 301-2P1-1
R1
12.2
-
5.5
8.3
1.1
4.6
ACS 311-2P1-1
R1
12.2
8.4
5.5
8.3
1.1
4.6
ACS 301-2P7-1
R1
15.7
-
7.1
10.7
1.5
4.6
ACS 311-2P7-1
R1
15.7
9.8
7.1
10.7
1.5
4.6
ACS 301-4P1-1
R1
22.4
-
10.7
13.0
2.2
4.6
ACS 311-4P1-1
R1
22.4
12.9
10.7
13.0
2.2
4.6
ACS 3_1-4P9-1
R2
-
10.6
13.2
19.8
3.0
13.0
ACS 3_1-6P6-1
R2
-
14.4
18.0
27.0
4.0
13.0
ACS 3_1-8P7-1
R2
-
21.0
24.0
27.0
5.5
13.0
Summary of Contents for ACS 300
Page 14: ...xiv ACS 300 User s Manual Table of Contents ...
Page 24: ...10 ACS 300 User s Manual Chapter 1 Overview of This Manual ...
Page 28: ...14 ACS 300 User s Manual Chapter 2 Mechanical Installation ...
Page 50: ...36 ACS 300 User s Manual Chapter 4 Control Connections ...
Page 60: ...46 ACS 300 User s Manual Chapter 6 Control and Parameter Logic ...