![ABB ACQ580-34 Hardware Manual Download Page 224](http://html.mh-extra.com/html/abb/acq580-34/acq580-34_hardware-manual_2546224.webp)
Diagnostics
■
Faults and warning messages
Warning A7AB Extension I/O configuration failure.
■
LEDs
The extension module has one diagnostic LED.
Description
Color
The extension module is powered up.
Green
Technical data
Into option slot 2 on the drive control unit
Installation
IP20 / UL Type 1
Degree of protection
See the drive technical data.
Ambient conditions
Cardboard
Package
Motor thermistor connection (60…61)
1.5 mm
2
Maximum wire size
DIN 44081 and DIN 44082
Supported standards
3.6 kohm ±10%
Triggering threshold
1.6 kohm ±10%
Recovery threshold
≤ 5.0 V
PTC terminal voltage
< 1 mA
PTC terminal current
< 50 ohm ±10%
Short-circuit detection
The PTC input is reinforced/double insulated. If the motor part of the PTC sensor and wiring are reinforced/double
insulated, voltages on the PTC wiring are within SELV limits.
If the motor PTC circuit is not reinforced/double insulated (ie, it is basic insulated), it is mandatory to use rein-
forced/double insulated wiring between the motor PTC and CMOD-02 PTC terminal.
Relay output (62…63)
1.5 mm
2
Maximum wire size
250 V AC / 30 V DC / 5 A
Maximum contact rating
1000 VA
Maximum breaking capa-
city
External power supply (40…41)
1.5 mm
2
Maximum wire size
24 V AC / V DC ±10% (GND, user potential)
Input voltage
25 W, 1.04 A at 24 V DC
Maximum power consump-
tion
224 CMOD-02 multifunction extension module (external 24 V AC/DC and isolated PTC interface)
Summary of Contents for ACQ580-34
Page 1: ... ABB DRIVES FOR WATER ACQ580 34 drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 14: ...14 ...
Page 24: ...24 ...
Page 50: ...50 ...
Page 60: ...60 ...
Page 70: ...70 ...
Page 94: ...94 ...
Page 110: ...110 ...
Page 122: ...122 ...
Page 132: ...Dimension drawing 132 External control unit option P906 ...
Page 140: ...140 ...
Page 144: ...144 ...
Page 164: ...164 ...
Page 184: ...Standard configuration E208 and E210 included 184 Dimension drawings ...
Page 185: ...Drive module with option B051 Dimension drawings 185 ...
Page 186: ...Drive module with options B051 H370 186 Dimension drawings ...
Page 187: ...LCL filter module Dimension drawings 187 ...
Page 190: ...190 ...
Page 208: ... Declaration of conformity 208 The Safe torque off function ...
Page 214: ...214 ...
Page 226: ...226 ...