ACH580-PCR/PDR
ACH580-PxR-052A-6
3
52
50
R5
Class T
80A
N/A
N/A
ACH580-PxR-062A-6
62
60
R5
Class T
80A
N/A
N/A
ACH580-PxR-077A-6
77
75
R5
Class T
100A
N/A
N/A
ACH580-PxR-099A-6
99
100
R7
Class T
150A
N/A
N/A
ACH580-PxR-125A-6
125
125
R7
Class T
175A
N/A
N/A
ACH580-PxR-144A-6
144
150
R8
Class T
200A
N/A
N/A
ACH580-PxR-180A-4
180
150
R2
Class T
300A
N/A
N/A
ACH580-PxR-240A-4
240
200
R2
Class T
350A
Class J
or RK1
400A Max
1) “PxR” represents both PCR and PDR.
2) PCR is rated 600Y/347V unless otherwise specified. For use on a solidly grounded Wye source only.
3) PCR supports Delta network configuration.
575 Volt
Nominal Output
Range
Base
Drive
Frame
Size
Internal Drive
Fuse Rating
External Fuse for
Disconnect Option
Type Code
1, 2
Drive
Current
Package
Power
A
HP
Class
Current
Rating
Class
Max Current