Drive of category C1
: drive of rated voltage less than 1000 V and intended for use in
the first environment.
Drive of category C2
: drive of rated voltage less than 1000 V and intended to be installed
and started up only by a professional when used in the first environment.
Note:
A
professional is a person or organization having necessary skills in installing and/or
starting up power drive systems, including their EMC aspects.
Drive of category C3
: drive of rated voltage less than 1000 V and intended for use in
the second environment and not intended for use in the first environment.
Drive of category C4
: drive of rated voltage equal to or above 1000 V, or rated current
equal to or above 400 A, or intended for use in complex systems in the second
environment.
■
Category C1
The drive complies with the conducted emission limits of the standard with the following
provisions:
1. The optional EMC filter is selected according to section
, and the filter is installed as specified in the EMC filter manual.
2. The motor and control cables are selected as specified in this manual. The EMC
recommendations are obeyed.
3. The maximum motor cable length does not exceed the specified maximum value.
See
EMC compatibility and motor cable length (page 144)
4. The drive is installed according to the instructions (IEC) given in this manual.
This product can cause radio-frequency inference. In a residential or domestic
environment, supplementary mitigation measures may be required in addition to the
requirements listed above for the CE compliance.
■
Category C2
This is applicable to drives with an internal EMC C2 filter. The filter is included to all
drive types as standard. However, for the UL(NEC) drive types it is not connected at
the factory. The user must re-connect it for the category C2 compliance.
The drive complies with the standard with the following provisions:
1. The motor and control cables are selected as specified in this manual. The EMC
recommendations are obeyed.
2. The maximum motor cable length does not exceed the specified maximum. See
EMC compatibility and motor cable length (page 144)
3. The drive is installed according to the instructions (IEC) given in this manual.
This product can cause radio-frequency inference. In a residential or domestic
environment, supplementary mitigation measures may be required in addition to the
requirements listed above for the CE compliance.
150 Technical data
Summary of Contents for ACH480
Page 1: ... ABB DRIVES FOR HVAC ACH480 drives Hardware manual ...
Page 2: ......
Page 4: ......
Page 14: ...14 ...
Page 22: ...22 ...
Page 28: ...28 ...
Page 38: ...38 ...
Page 44: ...44 ...
Page 60: ...60 ...
Page 86: ...86 ...
Page 110: ...110 ...
Page 114: ...114 ...
Page 122: ...122 ...
Page 156: ...Frame R1 Frame R1 front side IP20 UL open type 156 Dimension drawings ...
Page 157: ... Frame R1 bottom rear IP20 UL open type Dimension drawings 157 ...
Page 158: ... Frame R1 front side UL Type 1 kit installed 158 Dimension drawings ...
Page 159: ... Frame R1 bottom rear UL Type 1 kit installed Dimension drawings 159 ...
Page 160: ...Frame R2 Frame R2 front side IP20 UL open type 160 Dimension drawings ...
Page 161: ... Frame R2 bottom rear IP20 UL open type Dimension drawings 161 ...
Page 162: ... Frame R2 front side UL Type 1 kit installed 162 Dimension drawings ...
Page 163: ... Frame R2 bottom rear UL Type 1 kit installed Dimension drawings 163 ...
Page 164: ...Frame R3 Frame R3 front side IP20 UL open type 164 Dimension drawings ...
Page 165: ... Frame R3 bottom rear IP20 UL open type Dimension drawings 165 ...
Page 166: ... Frame R3 front side UL Type 1 kit installed 166 Dimension drawings ...
Page 167: ... Frame R3 bottom rear UL Type 1 kit installed Dimension drawings 167 ...
Page 168: ...Frame R4 Frame R4 front side IP20 UL open type 168 Dimension drawings ...
Page 169: ... Frame R4 bottom rear IP20 UL open type Dimension drawings 169 ...
Page 170: ... Frame R4 front side UL Type 1 kit installed 170 Dimension drawings ...
Page 171: ... Frame R4 bottom rear UL Type 1 kit installed Dimension drawings 171 ...
Page 172: ...172 ...
Page 180: ...180 ...
Page 198: ... Declaration of conformity 198 The Safe torque off function ...
Page 206: ...Dimensions 206 BIO 01 I O extension module ...
Page 212: ...Dimensions 3AXD50000031148 rev A 212 BREL 01 relay output extension module ...