Plumbing feeds - Floor fed
(Dimensions shown in mm)
Where wall entry is not possible, floor fed connections may also be made.
Note: when a peninsula layout in chosen, all visible pipework must also be boxed and identified as
a trip hazard.
Hot & Cold -
Feeds should be fed in 22mm. Feeds should terminate with
full bore isolating
valves.
Elbow isolation valves may be used to improve plumbing routing where possible.
Isolation valves must be located so that they are easily accessible.
Waste
- 40mm Waste outlet @ 3ltr/sec. Waste pipe highest point
should not exceed 120mm
from the floor.
End Wall Pre-install Plumbing
10
Floor fed peninsula plumbing
locations shown.
Note
: plumbing connections
terminate in the same location for
both left and right handed baths.
It is preferred that plumbing feeds
will terminate in the green area as
close to the bath centreline as
possible,
without entering the
orange margin
.
Pipework must not enter the room
in the location shown in
orange
, as
doing so will hinder installation.
When the bath is fitted 200mm or
more from the wall plumbing may
terminate along the bath centreline,
providing it
does not enter the
orange margin.
Plumbing pipes should terminate
the floor with centres a minimum of
50mm form the wall.
Figure 10.0
Gemini 2000 Installation Manual v1.3