Bath plumbing connections will be made externally to the bath.
All bath plumbing is located on a bath plumbing bracket, which holds internal pipework in the
correct position to prevent any interference with framework etc. Therefore it is essential that
internal plumbing remains as shown below.
In some instances the plumbing bracket may be removed if necessary to help with bath
installation.
One mounting bolt will be visible, however to gain access to the second mounting bolt remove
the waste flexi (S-trap side).
If the bracket is removed, it is critical that the bracket is checked once re-fitted into position to
ensure there has been no movement in pipework.
It is essential that a measurement of 180mm is maintained between the stem elbows and the
90 degree pipe manifold.
Note: failure to reinstall the bracket correctly may result in damage to the bath plumbing.
When reassembling the bracket to the frame for bath installation, use the 2 x M5 round head
allen bolts removed.
Gemini 2000 Installation Manual v1.3
21
Bath Plumbing Bracket
– End wall plumbing
180mm
Right Handed Bath
Left Handed Bath
180mm
Plumbing connections
exiting bath
Plumbing connections
exiting bath