Basic Functions
40
When loading the device in the charger or via the USB port, the no movement
alarm is deactivated.
Escape
The escape alarm is triggered when the sensor detects intense movements of the
mobile unit during a configurable time interval. As with the no movement alarm,
the sensor sensitivity can be set at three levels. It is recommended to test the sen-
sitivity of the escape alarm with the person being monitored in order to guarantee
reliable operation.
Setting alarm times
The settings are in the
>
Security
>
Alarm Sensor
menu (see page 112). Alarm
times are comprised as follows:
Delay
: This is the time that starts after the triggering event (man down, no
movement, escape). If the triggering event is interrupted for at least
2 seconds during this time, the delay restarts.
The delay can be configured separately for each alarm type.
Pre alarm
: This is the time where – if activated – an alarm tone is signalled on the
mobile unit before the alarm call number is dialled. To switch off the alarm
tone (and thus deactivate the alarm), you have to press the
Esc
softkey.
During Pre alarm, a display shows how much time remains until the alarm
call number is dialled.
If the triggering event is interrupted for at least 4 seconds (2 seconds for the
no-movement alarm) during this time, the delay restarts.
Setting the time for the Pre alarm is done for all alarm types together.
Other alarm parameter settings
Alarm number
: If the SOS emergency call number is predefined by the system,
this menu entry does not appear.
Open 100 / Aastra 800 systems only:
Always save the SOS emergency call
number with the prefixed R-key function (enquiry/hold). Then an
Event
Man down, No movement, Escape
detected
Delay
Pre alarm
with/without alarm
tone on the mobile unit
Dialling of the
alarm call number