VCC-X CONFIGURATION
VCC-X Operator Interface SD
24
VCC-X Con
fi
guration Screen Index
VCC-X Con
fi
guration Screen Index
The available Con
fi
guration Screens for the VCC-X Controller are
listed on the next few pages by sequential screen number. When each
VCC-X Controller is con
fi
gured for the
fi
rst time, it is best to start
with screen #1 and proceed to each screen in numerical order until
you have viewed all available Con
fi
guration Screens. This ensures
that you have seen all the available VCC-X Controller con
fi
gura-
tion possibilities and have the opportunity to change or accept the
defaults for each screen.
Once the unit is con
fi
gured and you decide to change one of the
screen options, it is helpful to know what screen number contains the
con
fi
guration you wish to change. With this in mind, the following is
a list of all the VCC-X Con
fi
guration Screens in numerical order with
a brief listing of the con
fi
guration feature available on each screen.
Screen #1
Sensor Scaling (Fahrenheit / Celsius)
Screen #2
RSM 1 & RSM 2 Installed
Screen #3
RSM 3 & RSM 4 Installed
Screen #4
RSM Type
Screen #5
EM1 Expansion Module Installed
Screen #6
MHGRV-X and MODGAS-X Installed
Screen #7
12 Relay E-BUS Expansion Module Installed
Screen #8
Preheat-X Controller Installed
Screen #9
HVAC Mode Enable Source
Screen #10
HVAC Mode Set By Remote Contact
Screen #11
SAT Reset Source
Screen #12
Reset Rate Interval
Screen #13
Space Sensor Type
Screen #14
Remote Space Sensor Board Address
Screen #15
Outdoor Sensor Type
Screen #16
Return Sensor Type
Screen #17
Static Pressure Control
Screen #18
Static/Fan Control Rate
Screen #19
Static Pressure Control Max Adjust
Screen #20
Fan Voltage Output - Min/Max
Screen #21
Supply Fan Cycle Mode
Screen #22
Fan Proving
Screen #23
Fan Starting Delay
Screen #24
Purge Mode Delay
Screen #25
Heat Type
Screen #26
Modulating Heat Output Signal - Min/Max
Screen #27
Cool Type
Screen #28
Mech Heat/Cool Alarm Delay
Screen #29
Economizer Control Type
Screen #30
Title 24 Economizer
Screen #31
Economizer in Unoccupied Mode
Screen #32
Economizer Enable Source
Screen #33
Economizer Control Loop Rate/Proportional
Window
Screen #34
Economizer Voltage Output - Min/Max
Screen #35
CO
2
Sensor Installed
Screen #36
Building Pressure Sensor Installed
Screen #37
Building Pressure Control
Screen #38
Building Pressure Control Rate
Screen #39
Building Pressure Control Max Adjust
Screen #40
Exhaust Fan Output
Screen #41
Heat Pump Con
fi
guration
Screen #42
WSHP Glycol Percentage
Screen #43
Aux Heat Type
Screen #44
Dehumidi
fi
cation Control
Screen #45
Humidity Control Sensor Type
Screen #46
Reheat Control
Screen #47
Type of Air
fl
ow Station
Screen #48
Monitor Outdoor Air Air
fl
ow
Screen #49
Control Outdoor Air Air
fl
ow
Screen #50
Outdoor Air
fl
ow Duct Size
Screen #51
Monitor Supply Air Air
fl
ow
Screen #52
Supply Air
fl
ow Duct Size
Screen #53
Monitor Return Air Air
fl
ow
Screen #54
Return Air
fl
ow Duct Size
Screen #55
Monitor Exhaust Air
fl
ow
Screen #56
Exhaust Air
fl
ow Duct Size
Screen #57
Morning Warm Up Type
Screen #58
AHU Uses Schedule Number
Screen #59
Daylight Adjustment Start/Stop Date
Screen #60
Trend Log Rate
Screen #61
Emergency Shutdown
Screen #62
Dirty Filter
Screen #63
Broadcast Outdoor Air Temperature
Screen #64
Broadcast Outdoor RH
Screen #65
Broadcast Space Temperature
Screen #66
Broadcast Space Humidity
Screen #67
Broadcast CO
2
Screen #68
Broadcast Building Pressure
Screen #69
Broadcast to Boxes
Screen #70
Cool Stage Up and Down Delays
Screen #71
Cool Stage Min Run and Min Off Delays
Screen #72
Heat Stage Up and Down Delays
Screen #73
Heat Stage Min Run and Min Off Delays
Screen #74
Heat Pump Delays
Screen #75
Heat/Cool Changeover Delay
Screen #76
Return Air Bypass Control
Screen #77
Morning Cool Down Type
Screens
#78-84
VCC-X Relay 1-8 Con
fi
guration Screens
Screens
#85-89
EM1 Relays 1-5 Con
fi
guration Screens
Screen
#90-101
12 Relay Con
fi
guration Screens