54
13-2 Output Terminal
Equivalent circuit diagram
Contact rating
250 VAC 0.1 A
30 VDC 0.5 A
Note on connecting output terminals
Use a load within the specified rating to prevent over-voltage or over-current from
destroying the MOS FET relay.
Connect a spark killer to the load appropriate to AC/DC.
Do not short-circuit the load. It may damage the MOS FET relay.
AD-4532B interior
AD-4532B interior
Non-polar
MOS FET relay
31 to 33
Load
Load
Varistor
Spark killer
31 to 33
34
AC power supply
DC power supply