Explanation of types of installation
Note
Make sure that the chimney flue discharges into an area approved for this
type of installation.
3.10.3
Concentric connections
The table shows the requirements for concentric systems.
Warning
Install flue gas discharge pipe runs with a run-off of 5 mm per metre towards
the water heater.
Flue gas discharge requirements for concentric systems (C13, C33)
Caution
Both conditions stated in the table must be fulfilled.
Even if you use less than the stated maximum number of bends, the maximum
pipe length
still
may not be exceeded.
Even if you use less than the stated maximum pipe length, the maximum
number of bends
still
may not be exceeded.
The following example illustrates how to use the table.
Installation type
Description
B23
Air for combustion is drawn from the boiler room.
C13
Concentric and/or parallel wall flue terminal.
C33
Concentric and / or parallel roof flue terminal
C43
Water heaters on common air supply and flue gas discharge (concentric
and/or parallel) in multi-storey building.
C53
Air supply and flue gas discharge terminal types mixed.
C63
Water heaters supplied without flue gas discharge materials and/or terminal.
These water heaters must be installed in compliance with local regulations.
Appliance
Diameter
Maximum
length
Maximum
number of
90
o
bends
SGS 28, 30, 50, 60
100/150 mm
40 m
7
SGS 80, 100, 120
130/200 mm
15 m
4
Summary of Contents for SGS - 100
Page 7: ...4 Instruction manual SGS gis...
Page 11: ...Contents 8 Instruction manual SGS...
Page 23: ...Working principle of the water heater 20 Instruction manual SGS 2 gis...
Page 37: ...Installation types 34 Instruction manual SGS Installation 3...
Page 57: ...Conversion to a different gas category 54 Instruction manual SGS 4 is...
Page 65: ...Draining 62 Instruction manual SGS 6 gis...
Page 71: ...Status of the water heater 68 Instruction manual SGS 8 gis...
Page 75: ...Shutting down 72 Instruction manual SGS 10 gis...
Page 103: ...Service interval 100 Instruction manual SGS 14 is...
Page 112: ...Instruction manual SGS 109 is...
Page 119: ...Instruction manual SGS 116...