3M Touch Systems Proprietary Information
9
Setting jumpers
RS-232 communication
Use a standard cable for RS-232 communications. Alternatively, make a cable for
RS-232 communications using the pin-out shown in Table A. The maximum cable
length is 50 feet.
RS-422 communication
To make a cable for RS-422 communications, use the pin-out shown in Table B.
For maximum cable length, refer to the EIA RS-422 Specification Standard.
Table A: COM A RS-232 connector pin-out
Pin
Signal
Description
In/Out
1
CGND
Shield Ground
1
---
2
TXD
Transmit Data
OUT
3
RXD
Receive Data
IN
4
RTS
Request To Send
OUT
5
CTS
Clear To Send
IN
6
DSR
Data Set Ready
IN
7
SGND
Signal Ground
---
8
DCD
Data Carrier Detect
IN
20
DTR
Data Terminal
Ready
OUT
22
RI
Ring Indicator
IN
1
Connect only one end of the cable to shield ground.
Table B: COM A RS-422 connector pin-out (full duplex)
Pin
Signal
Description
In/Out
1
GND
Shield Ground
1
---
9
TX+
Balanced Transmit data +
OUT
10
TX-
Balanced Transmit data -
OUT
14
RX+
Balanced Receive data +
IN
15
RX-
Balanced Receive data -
IN
1
Connect only one end of the cable to shield ground.
Summary of Contents for Dynapro ET 3170 Terminal Series B
Page 6: ......
Page 10: ......
Page 14: ......
Page 18: ......
Page 22: ......
Page 26: ......
Page 30: ......
Page 32: ......
Page 34: ......
Page 36: ......
Page 44: ......
Page 88: ......
Page 98: ......
Page 103: ......
Page 106: ......
Page 107: ......
Page 113: ......
Page 115: ......
Page 117: ......