3e-525A–3 Wireless Access Point
Chapter 2: Hardware Installation
16
29000167-001 B
Connect
RF Antenna
for AP
Connect
RF Antenna
for AP
LAN "Local"
Ethernet
Port
110V
Power
Ethernet switch/hub
Connect
RFAntenna
for Bridge/
Repeater
Power
Injector
WAN "Uplink"
Ethernet
Port / PoE
Outdoor Protection Kit Installation
If any portion of this system (3e–525A–3 enclosure, antennas, cables
etc.) is mounted outdoors, it is strongly recommended that the Outdoor
Protection Kit (3e-OPK-3) for this product be used. This kit contains
lightning arrestors and ground cables designed for this product.
If the system is mounted outdoors where CE Mark certifi cation is
required, use of the Outdoor Protection Kit (or equivalent) is
MANDATORY
. Failure to install this protection will void the warranty.
The Outdoor Protection Kit (3e-OPK-3 contains the following items:
• 10-inch, 10AWG wire with #8 ring terminal on one end and a #10
ring terminal on the other end
• 12-inch, 10 AWG wire with #8 ring terminal on one end and a #10
ring terminal on the other end
• 18-inch, 10 AWG wire with #8 ring terminal on one end and a #10
ring terminal on the other end
• Three lightning arrestors, Reverse N Polarity
NOTE
: You (the user) are required to ensure that the connection to a
proper earth ground is made by properly certifi ed and authorized person-
nel and must conform to all applicable codes and regulations. The materi-
als required to connect to a proper ground are defi ned by local conditions
and must be procured locally to ensure the correct safety environment is
achieved. The cable used to connect to a proper ground must be AWG 10
or heavier. This cable should be kept as short as possible.