Getting Started
5-7
If you cannot see the main banner or it displays
incorrectly, it may be that:
■
Your terminal is not configured as a VT100 terminal.
Check that your terminal is set up to operate with
the same parameters that the hub’s console port
uses. The console port’s autoconfigure option only
operates if your terminal uses correct parameters.
The maximum speed is 19200 baud. For
information on the console port, see
“Connecting a
Modem to the Console Port” on page 5-13
.
■
Autoconfigure is disabled.
If you are unable to obtain the banner screen, it is
possible that the autoconfigure option has been
disabled. Check the configuration of the terminal.
If you cannot resolve the problem, refer to
“Problems
When Using VT100” on page 6-3
for more problem
solving information.
Logon
You must enter your user name and password in the
Logon screen, as shown in
Figure 5-3
, before you
can use the management facility.
Figure 5-3
Logon Screen
16710.bk : MANVT100.FRM Page 7 Tuesday, October 7, 1997 11:38 AM