H3C S9500 Series Routing Switches
Chapter 3 Switch Installation
3-10
1)
Clutch the air filter cover by the upper and lower edges with your index finger and
the thumb, and gently remove the air filter cover from a PSU.
Note:
You can pull out the PSU handle only after removing the air filter cover.
2)
Slide the PSU smoothly along the guide rails, until it snaps into the backplane.
Figure 3-9
Install an AC PSU
3)
Fasten the captive screws on both sides of the PSU with a Philips screwdriver and
install the removed air filter cover onto the PSU.
4)
Check that the power switch on the PSU is in the OFF position.
II. Installing NEPS3500-A
NEPS3500-A contains two sub-PSU slots. You can configure one or two 1800 W
sub-PSUs. Follow these steps to install NEPS3500-A:
1)
Install a NEPS3500-A enclosure into the switch.
2)
Install one to two 1800 W sub-PSUs into the NEPS3500-A enclosure.