Table 2-5
Specifications for AC PSUs
Specifications
Item
NEPS600-A
NEPS1200-A
NEPS2000-A
NEPS3500-A
Model S9502
S9505
S9508/S9512 S9508/S9512
Rated
voltage
range
100 to 240 VAC,
50 Hz or 60 Hz
100 to 240 VAC,
50 Hz or 60 Hz
100 to 120 VAC,
60 Hz
200 to 240 VAC,
50 Hz
100 to 240 VAC,
50 Hz or 60 Hz
Input
voltage
range
90 to 264 VAC,
50 Hz or 60 Hz
90 to 264 VAC,
50 Hz or 60 Hz
90 to 264 VAC,
50 Hz or 60 Hz
90 to 264 VAC,
50 Hz or 60 Hz
Max
input
current
7.5 A
15 A
15 A
Single 1800W
sub-PSU:15 A
Two 1800W
sub-PSUs: 30 A
Table 2-6
Specifications for DC PSUs
Specifications
Item
NEPS600-D
NEPS1200-D
NEPS2000-D
NEPS3500-D
Model S9502
S9505
S9508/S9512
S9508/S9512
Rated
voltage
range
–48 VDC to
–60 VDC
–48 VDC to –60
VDC
–48 VDC to –60
VDC
–48 VDC to –60
VDC
Input
voltage
range
–36 VDC to
–72 VDC
–36 VDC to –72
VDC
–36 VDC to –72
VDC
–36 VDC to –72
VDC
Max
input
current
12.5 A
25 A
42 A
75 A
Max
output
power
600 W
1,200 W
2,000 W
3,500 W
2.2.7 Space Requirements