68
15. Appendix D - Technical Conditions for BLUESTAR Installation
15.1. Subrack
Dimensions (W x H x D)
482 x 133 x 360 mm (84HP x 3U x 360 mm)
Weight (full configuration)
9,800 g
Power supply
100-240V AC / 50-60Hz
Power input
max. 230VA
15.2. GSM
Mobile network type
GSM phase II
Transmission output per channel
900MHz / 2W, 1800MHz / 1W or
850MHz / 2W, 1900MHz / 1W
SIM cards
plug-in small
3V
VF connector
GSM boards with GM22 modules -FME 50ohm
GSM boards with TC35i,MC45i,GM47(8)
modules –SMA 50ohm
Length of antenna cable (RG58)
Max. 20m
15.3. PRI Interface
Interface
1x or 2x ISDN PRI
Signaling
Q.931-EDSS1, QSIG (1x PRI)
Type (NT or TE)
NT/TE
TEI number
0 – 63
Clock (master or slave)
Master/Slave
Connector RJ 45, Rxpin, Txpin 2x Switchable RJ45
(Rx-3,6 Tx-4,5 / Rx-4,5 Tx-3,6)
D channel timeslot
16
15.4. Temperature
Working temperature range
0°C to + 50°C
Relative humidity
max. 95% at 40°C
Air – condition
optional
15.5. Remote Control Line types
Type of line
Serial line (COM1,2), Analogue modem
(COM2), ISDN modem (COM2), Ethernet
10baseT, inband DATA in PRI ISDN