Chapter 35 Access Control
GS2200 Series User’s Guide
267
intrusionlock
IntrusionLockEventOn
1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when intrusion lock
occurs on a port.
loopguard
LoopguardEventOn
1.3.6.1.4.1.890.1.5.8.55.27.2.1
1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.59.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when loopguard shuts
down a port.
errdisable
errdisableDetect
1.3.6.1.4.1.890.1.5.8.55.130.4.
1
1.3.6.1.4.1.890.1.5.8.56.130.4.
1
1.3.6.1.4.1.890.1.5.8.59.130.4.
1
1.3.6.1.4.1.890.1.5.8.60.130.4.
1
This trap is sent when an error is detected
on a port, such as a loop occurs or the
rate limit for specific control packets is
exceeded.
errdisableRecovery
1.3.6.1.4.1.890.1.5.8.55.130.4.
2
1.3.6.1.4.1.890.1.5.8.56.130.4.
2
1.3.6.1.4.1.890.1.5.8.59.130.4.
2
1.3.6.1.4.1.890.1.5.8.60.130.4.
2
This trap is sent when the Switch ceases
the action taken on a port, such as
shutting down the port or discarding
packets on the port, after the specified
recovery interval.
fanspeed
FanSpeedEventOn 1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the fan speed goes
above or below the normal operating
range.
FanSpeedEventClear 1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the fan speed
returns to the normal operating range.
poe
PwrPortFailedEventOn 1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the port is turned
off to supply power due to overloading,
over system buget, or short circuit.
PwrPortFailedEventClear 1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the port returns to
the normal state and has the ability to
supply power.
PsePwrFailedEventOn 1.3.6.1.4.1.890.1.5.8.56.27.2.1
1.3.6.1.4.1.890.1.5.8.60.27.2.1
This trap is sent when the power supply
of PoE failed. The trigger situation
includes internal/external power supply
failure, external fan speed failure, and
external power has exceed normal
temperature.
PsePwrFailedEventClear 1.3.6.1.4.1.890.1.5.8.56.27.2.2
1.3.6.1.4.1.890.1.5.8.60.27.2.2
This trap is sent when the power supply
of PoE returns to the normal state.
Table 112
SNMP System Traps (continued)
OPTION
OBJECT LABEL
OBJECT ID
DESCRIPTION
Содержание GS2200 Series
Страница 15: ...15 PART I User s Guide...
Страница 16: ...16...
Страница 31: ...31 PART II Technical Reference...
Страница 32: ...32...
Страница 76: ...Chapter 8 Basic Setting GS2200 Series User s Guide 76...
Страница 92: ...Chapter 9 VLAN GS2200 Series User s Guide 92 Figure 60 Port Based VLAN Setup Port Isolation...
Страница 230: ...Chapter 29 Error Disable GS2200 Series User s Guide 230...
Страница 248: ...Chapter 33 ARP Learning GS2200 Series User s Guide 248...
Страница 302: ...Appendix A Changing a Fuse GS2200 Series User s Guide 302...
Страница 306: ...Appendix B Common Services GS2200 Series User s Guide 306...
Страница 309: ...Appendix C Legal Information GS2200 Series User s Guide 309 ROHS...
Страница 310: ...Appendix C Legal Information GS2200 Series User s Guide 310...
Страница 320: ...Index GS2200 Series User s Guide 320...