Chapter 24 AAA
GS2200 Series User’s Guide
183
Login
These fields specify which database the Switch should use (first, second and third) to
authenticate administrator accounts (users for Switch management).
Configure the local user accounts in the Access Control > Logins screen. The
and RADIUS are external servers. Before you specify the priority, make sure you have set
up the corresponding database correctly first.
You can specify up to three methods for the Switch to authenticate administrator accounts.
The Switch checks the methods in the order you configure them (first Method 1, then
Method 2 and finally Method 3). You must configure the settings in the Method 1 field. If
you want the Switch to check other sources for administrator accounts, specify them in
Method 2 and Method 3 fields.
Select local to have the Switch check the administrator accounts configured in the Access
Control > Logins screen.
Select radius to have the Switch check the administrator accounts configured via your
RADIUS server.
Select to have the Switch check the administrator accounts configured via your
server.
Authorization
Use this section to configure authorization settings on the Switch.
Type
Set whether the Switch provides the following services to a user.
•
Exec: Allow an administrator which logs in the Switch through Telnet, SSH or FTP to
have different access privilege level assigned via the external server.
•
Dot1x: Allow an IEEE 802.1x client to have different bandwidth limit or VLAN ID
assigned via the external server.
Active
Select this to activate authorization for a specified event types.
Method
Select whether you want to use RADIUS or for authorization of specific types of
events.
RADIUS is the only method for IEEE 802.1x authorization.
Accounting
Use this section to configure accounting settings on the Switch.
Update Period
This is the amount of time in minutes before the Switch sends an update to the accounting
server. This is only valid if you select the start-stop option for the Exec or Dot1x entries.
Type
The Switch supports the following types of events to be sent to the accounting server(s):
•
System - Configure the Switch to send information when the following system events
occur: system boots up, system shuts down, system accounting is enabled, system
accounting is disabled
•
Exec - Configure the Switch to send information when an administrator logs in and logs
out via the console port, telnet or SSH.
•
Dot1x - Configure the Switch to send information when an IEEE 802.1x client begins a
session (authenticates via the Switch), ends a session as well as interim updates of a
session.
•
Commands - Configure the Switch to send information when commands of specified
privilege level and higher are executed on the Switch.
Active
Select this to activate accounting for a specified event types.
Broadcast
Select this to have the Switch send accounting information to all configured accounting
servers at the same time.
If you don’t select this and you have two accounting servers set up, then the Switch sends
information to the first accounting server and if it doesn’t get a response from the
accounting server then it tries the second accounting server.
Table 64
Advanced Application > AAA > AAA Setup (continued)
LABEL
DESCRIPTION
Содержание GS2200 Series
Страница 15: ...15 PART I User s Guide...
Страница 16: ...16...
Страница 31: ...31 PART II Technical Reference...
Страница 32: ...32...
Страница 76: ...Chapter 8 Basic Setting GS2200 Series User s Guide 76...
Страница 92: ...Chapter 9 VLAN GS2200 Series User s Guide 92 Figure 60 Port Based VLAN Setup Port Isolation...
Страница 230: ...Chapter 29 Error Disable GS2200 Series User s Guide 230...
Страница 248: ...Chapter 33 ARP Learning GS2200 Series User s Guide 248...
Страница 302: ...Appendix A Changing a Fuse GS2200 Series User s Guide 302...
Страница 306: ...Appendix B Common Services GS2200 Series User s Guide 306...
Страница 309: ...Appendix C Legal Information GS2200 Series User s Guide 309 ROHS...
Страница 310: ...Appendix C Legal Information GS2200 Series User s Guide 310...
Страница 320: ...Index GS2200 Series User s Guide 320...