Appendix B
Table
of Cable Connections
B-23
Serial
No.
Cable Name
Connection of Terminal A
Connection of Terminal B
Remarks
13 ACDX03
MPD_HP
Heater
Power lightning arrester (blue, brown)
14 ACDX01
POWER (at the bottom of
the cabinet)
Grounding point (black)
15
ACDX02
MPD_X1
Power lightning arrester
16 ACDX04
ACDX01_A
External
AC
power
The configuration in
case that AC power is
supplied
17 F-DC
PWR-001
POWER (at the bottom of
the cabinet)
Power lightning arrester
18
F-DC PWR-002
F-DC PWR-001_A
External -48V power
19 F-DC
PWR-003
(Blue) MPD_V-
(Black) MPD_V+
Power lightning arrester
The configuration in
case that DC power
is supplied
20 RF25
TRX_TX
MPA_IN
21 RF32
DIV_RX
LNA-1_IN
22 RF33
LNA-2_IN
MDUP1900_RX
23 RF34
MPA_OUT
MDUP1900_TX
24 RF35
TRX_RX0
LNA-1_RFOUT1
25 RF36
TRX_RX1
LNA-2_RFOUT1
26 RF37
DIV_ANT
RFE-ANT0 (at the bottom of the
cabinet)
27 RF38
RFE-ANT1 (at the bottom
of the cabinet)
MDUP1900_ANT
28
RF40
Middle hole of BRFS_X1
Middle hole of BRFS_X3
29
RF41
RFM_X7
Middle hole of RFM_X3
30 F-FAN-005
COMMAN (at the bottom of
the cabinet)
MPD
31 F-FAN-006
COMMAN (at the bottom of
the cabinet)
External fan
B.20 Cable Connections in R192T Double-carrier Remote Stations
Table B.20-1 Cable Connections in R192T Double-carrier Remote Stations
Serial
No.
Cable Name
Connection of Terminal A
Connection of Terminal B
Remarks
1 DCDX01
BRFS_X5
MPD_X11
2 DCDX02
MPD_X6
MPA
3 DCDX03
MPD_X7
LNA
4 RSTDX
MPD_X5
BRFS_X6