Table 3

Electric actuators MODACT MONED, MOPED, MONEDJ

– Specification of meaning of the 6th to 10th place of the type number

Place in the type number

 ...1

st 

2

nd 

3

rd

  4

th

  5

th

    6

th

 

7

th

 

8

th

 

9

th

 

10

th

 

11

th

Type number

 .......................5  2  0  3  x  .  x 

x 

x 

x 

x E D (J)  

x

If one of numerals 1, 3, 5, 7 or 9 is on the 9th place of the type number the character from Table 4 is on the 7th place. 
If one of numerals 2, 4, 6 or 8 is on the 9th place of the type number the character from Table 5 is on the 7th place.

Outfit 

0  1  2  3  4  5  6  7  8  9  A  B  C  D  E  F  H  J  K  L  M  N  V  W

Local control 

  x    x    x    x    x    x    x    x    x    x    x    x

Display 

 

  x  x   

  x  x   

  x  x   

  x  x   

  x  x   

  x  x

Contactors or contact-less switching 

 

 

 

  x  x  x  x   

 

 

  x  x  x  x   

 

 

  x  x  x  x

                            transmitter 

 

 

 

 

 

 

 

  x  x  x  x  x  x  x  x  x  x  x  x  x  x  x  x

                            regulator 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  x  x  x  x  x  x  x  x

Connector

Bushings

Version

Connecting dimensions

 

Shape A  

5  

F

Shape B1  

6  

G

Shape C  

7  

H

Shape D  

8  

J

Shape E  

9  

K

Table 4 – actuator fitted with electronics DMS2 ED

6th place of type number

7th place of type number

Analog

module

The  actuators  MODACT  MONEDJ  are  fitted  with  single-phase  electric  motors  Siemens  series  1LF7...  with  running  and  starting-up  capacitors.  

The manufacturer guarantees 60,000 and 100,000 start-ups for two-pole electric motors (ca 2800 r.p.m.) and four-pole electric motors (ca 1400 r.p.m.), 
respectively. Then, it is necessary to replace the centrifugal disconnector of the starting-up capacitor – it is available at ZPA Pečky a.s. 

In ZPA Pečky a.s., electric motors of power up to 0.37 kW are fitted with a triac disconnector that extends the service life to 350,000 start-ups. 
If the actuator with a single-phase electric motor is to be used for regulating purposes, it is necessary to take this fact into consideration in setting-up 

the regulation process (frequency of regulating interventions). 

The expected working regime of the actuators MONEDJ should be discussed with the marketing department of ZPA Pečky, a.s.

 

– Mark of actuators filled with oil. Other actuators are filled with plastic lubricant.

Table 2  – Electric actuators MODACT MONEDJ 

– basic parameters 

 

– supply voltage 1 x 230 V, 50 Hz, protective enclosure IP 55

 

Type marking

Torque [Nm]

   Tripping  Starting

Contr

ol

Adjusting 

speed

[1/min]

Working 

stroke

[revol.]

Electric motor

Power

[kW]

RPM

[1/min]

In

(230 V) 

[A]

IZ
In

Weight

[kg]

Type

of el. motor

Typ 

maziv

a

Type No.

basic

1 2 3 4 5

additional

   6 7 8 9 10 11

MONEDJ 40/75-25 

 

75 

25 

 

 

JMO 71-4S  0,25  1400 

1,89 

3,4 

27 

 

 x x 2 x NEDJ x 

MONEDJ 40/50-40 

20 

– 

40

 

50 

40 

 

 

JMO 71-4S  0,25  1400 

1,89 

3,4 

27 

 

 x x 3 x NEDJ x 

MONEDJ 40/60-50 

  

60 

50 

 

  JMO 71-2S  0,37  2880 

2,53 

3,9 

27 

 

 x x 4 x NEDJ x 

MONEDJ 40/60-80 

 

60 

80 

 

  JMO 71-2M  0,55  2860 

3,41 

4,0 

27 

52 030 

 x x 5 x NEDJ x 

MONEDJ 80/135-25  C  40 – 80 

135 

25 

2-1980

    JMO 71-4M  0,37  1400 

2,61 

3,4 

27 

connecting   x x 8 x NEDJ x 

MONEDJ 70/90-40 

C  40 – 70 

90 

40 

 

  JMO 71-4M  0,37  1400 

2,61 

3,4 

28 

dimension F10   x x 9 x NEDJ x 

MONEDJ 75/100-50  C  40 – 75 

100 

50 

 

  JMO 71-2M  0,55  2860 

3,41 

4,0 

28 

 

 x x A x NEDJ x 

MONEDJ 110/143-25  C    80 – 110 

143 

25 

 

  JMO 71-4M  0,37  1400 

2,61 

3,4 

28 

 

 x x E x NEDJ x 

MONEDJ 100/130-40  C    63 – 100 

130 

40 

 

 

JMO 80-4S  0,55  1395 

3,85 

3,8 

41 

 

 x x 3 x NEDJ x 

MONEDJ 95/124-63   

63 – 95 

124 

63 

 

  JMO 80-4M  0,75  1400 

4,7 

4,0 

42 

 

 x x 4 x NEDJ x 

MONEDJ 100/130-80   

63 – 100

 

130 

80 

 

  JMO 80-2M  1,1 

2800 

6,6 

4,4 

43 

 

 x x E x NEDJ x 

MONEDJ 100/130-100   

 

130 

100 

 

  JMO 90-4L 

1,5 

1400 

8,68 

3,5 

50 

52 031 

 x x 5 x NEDJ x 

MONEDJ 95/124-145   

63 – 95 

124 

145 

 

  JMO 90-2S 

1,5 

2830 

9,11 

4,5 

51 

connecting   x x F x NEDJ x 

MONEDJ 150/195-40    100 – 150 

195 

40 

2-1400    JMO 80-4M  0,75  1400 

4,7 

4,0 

41 

dimension F14   x x 9 x NEDJ x 

MONEDJ 160/208-65   

100 – 160

 

208

 

65 

 

  JMO 90-4L 

1,5 

1400 

8,68 

3,5 

42 

 

 x x A x NEDJ x  

MONEDJ 160/208-80   

  

 

80 

 

  JMO 90-2S 

1,5 

2830 

9,11 

4,5 

43 

 

 x x H x NEDJ x 

MONEDJ 130/170-145    100 – 130 

170 

145 

 

  JMO 90-2L 

2,2 

2850 

13,02  4,8 

51 

 

 x x J x NEDJ x 

MONEDJ 250/325-40    160 – 250 

325 

40 

 

 

JMO 90-4L 

1,5 

1400 

8,68 

3,5 

45 

52 032 

 x x 3 x NEDJ x 

MONEDJ 220/286-80    160 – 220 

286 

80 

 

  JMO 90-2L 

2,2 

2850 

13,02  4,8 

49 

connec. dim. F14  x x 5 x NEDJ x

Содержание MODACT MONED

Страница 1: ...10 18 MOUNTING INSTRUCTIONS Electric Multi turn Actuators Type numbers 52 030 52 036 Type numbers 52 030 52 032...

Страница 2: ...ZPA Pe ky a s is certified company in accordance with ISO 90001 as amended...

Страница 3: ...eric precipitations under an angle up to 60 from the vertical is prevented The electric actuator must be installed in a place where cooling air has a free access Minimum distance from a wall for acces...

Страница 4: ...orque Mv According to SN EN 60 034 1 the actuators can also be operated in the S4 mode interrupted operation with acceleration intervals The load factor N N R shall be maximum 25 per cent the longest...

Страница 5: ...10 15 50 Hz 2 3 x 220 380 V 10 15 50 Hz 3 5 MODACT MONEDJ 1 x 230 V 10 15 50 Hz 2 1 x 220 V 10 15 50 Hz 3 5 or according to data on the rating plate Actuators designed to operate at another voltage an...

Страница 6: ...he valve Torque limit switches in the actuator are set and work when the actuator is under voltage When using the manual control ie actuator is controlled mechanically the torque limit switches doesn...

Страница 7: ...nal board for connection to external circuits This terminal board uses screw terminals allowing conductors with a maximum cross section 4 mm2 to be connected Access to the terminal board is obtained a...

Страница 8: ...e gearing the central wheel of the differential gear located in the load bearing box of the electric actuator force gear In motor control the crown wheel of the epicyclic differential is held in const...

Страница 9: ...onnection of computer for setting and diagnostics Torque unit Source unit electronic power supply user s terminal board connection of power supply and control signals 2 torque relays 2 position relays...

Страница 10: ...indow Parameters of the setting program column Access the word NO designates parameters that cannot be changed by the user change of these parameters is blocked Relay READY It usually signalizes error...

Страница 11: ...does not react to the set position and can only be stopped by the torque relay In controlling from menu MOTOR no torque may be induced The torque must be left manually If during adjustment the torque...

Страница 12: ...button MENU for at least 2 s The setting menu will also be left in case that no push button is pressed within 1 minute MENU 1 Setting of tripping torques After entering the menu by means of push butto...

Страница 13: ...risk of damaging the actuator by wrong wiring In controlling the actuator from program DMS2 its run is stopped when any torque is induced Working torque Check and if necessary set the value of working...

Страница 14: ...1 10 Output of position signal 4 20 mA 20 4 mA Function READY combined error Note Signal READY is brought out as contact of the relay on the terminal board If the state ERROR or WARNING is not detect...

Страница 15: ...industrial bus does not communicate or not added in parameter CAN of configuration 26 CAN X Error of bus CAN short circuit interruption only sensor communicates 27 Fieldbus activity X Connection to in...

Страница 16: ...MI DAL PO 16 PZ 19 15 4 17 MZ 12 3 13 11 RU OR 5V M stn ovl d n M D READY 6 5 O Z TOP 1 2 N 8 7 N F160mA N polohy 2x L COMM Analogov modul L mA Pas vn v stup Aktivn v stup D lkov povoleno zav rej Mot...

Страница 17: ...10 MO MENU P C O Sn ma momentu Sn ma Zdrojov deska 30 29 N U 4 6 C NO C 24 26 27 NO NC NO C NC NO NC C 20 22 21 17 16 19 18 NC C C M 13 12 3 W1 V1 15 W2 V2 1 5 U1 U2 3 2 23 6 5 3 4 PE N U PE 2 42 L CO...

Страница 18: ...p 3x400 V D lkov povoleno D lkov D lkov M3 U1 W1 V1 E0002 V proveden bez m stn ho ovl d n se propojka ze svorky U zapoj na svorku 2 otev rej zav rej Example of wiring diagram Substitution of electro m...

Страница 19: ...W N N polohy 2x PE IN IN L COMM Analogov modul L mA Pas vn v stup Aktivn v stup 4 20mA 3x400 V U2 W2 V2 U1 W1 V1 TH E0003 U proveden bez m stn ho ovl d n se propojka ze svorky U zapoj na svorku 2 Sour...

Страница 20: ...2 U2 L Analogov modul COMM L IN IN PE 2x polohy N N W W V V F160mA U N 7 8 N 2 1 TOP Z O 5 6 READY D M M stn ovl d n 5V OR RU 11 13 3 12 MZ 17 4 15 19 PZ 16 PO MI DAL T P 23 18 22 21 24 SO SZ U 20 COM...

Страница 21: ...switching of electric motor EM0004 ZBT Torque sensor Position sensor Analog module Active output Passive output Note Here contacts of relays MO MZ SO SZ are shown with power supply switched off with p...

Страница 22: ...wiring diagram of electronics DMS2 ED in version Control with contact less switching of electric motor with connector connection EM0043K ZBT Torque sensor Position sensor Analog module Passive output...

Страница 23: ...terminals for connecting external control signals input of signal SAFE information on external failure relay total of five four signalling can be set for reporting of position torque or other operati...

Страница 24: ...k and if necessary change other parameters Control signal 4 20 mA 20 4mA 0 20 mA 20 0 mA 2 position Bus Insensitivity 1 1 0 Function SAFE Open Close Stop To position Active SAFE O V 230 V Time of bloc...

Страница 25: ...ly Overview of MENU Name Parameter value Meaning 1 JAZ LANGUAGE CESKY Menu LANGUAGE ENGLISH 2 POLOHA O Z POL OTEVR End limit position Open or Closed POL ZAVRENO 3 KALIBRACE SPUSTIT Starting of autocal...

Страница 26: ...rminate the setting regime Setting end limit positions by means of push buttons of local control Shift the change over switch LOCAL REMOTE to position OFF Keep pressing push button STOP to enter the s...

Страница 27: ...27 Connector to connect local display not used here Terminal board of DMS2 Analog Terminal board of DMS2 Profibus...

Страница 28: ...th suffix par in the example in the figure the file 52 030 par is created in the directory Flash The file can serve as a back up for the case that it will be necessary to replace the position sensor i...

Страница 29: ...30V U test TH 3 5 1 6 4 2 A1 A2 21 22 A1 A2 KZ 3 5 1 6 4 2 21 22 PE PE U N 8 7 N U V V W W N N 3x400 V RO Aktivn Pas vn v stup KO M3 U2 W2 V2 U1 W1 V1 E0006 22 21 20 26 25 24 23 SAFE N230V N24 48V N23...

Страница 30: ...SAFE DMS2 D RZ TOP TP U V W ERR RE1 RE2 RE3 RE4 PE IN IN L COMM L mA v stup v stup 0 4 20mA U 60V 60 230V U zav rej otev rej U 60V 60 230V U test TH 3 5 1 6 4 2 A1 A2 21 22 A1 A2 KZ 3 5 1 6 4 2 21 22...

Страница 31: ...rej U 60V 60 230V U test PE PE U 3 4 1 2 U V V W W N N 3x400 V 6 Aktivn v stup Pas vn v stup E0031 M3 U2 W2 V2 U1 W1 V1 TH F R Elektronick 4 2 1 3 6T3 4T2 2T1 brzda 5L3 3L2 1L1 0V 12V RZ RO 22 21 20...

Страница 32: ...v stup 0 4 20mA U 60V 60 230V U Zav rej Otev rej U 60V 60 230V U Test PE PE 3 4 1 2 W W N N 5 RC COMM RNC RNO Aktivn Pas vn U2 U1 Z2 Z1 M1 C C 1 3 2 4 KZ A1 5 A2 6 1 3 5 2 6 4 KO A1 A2 TH E0007 COM OP...

Страница 33: ...12 znak DMS2 S VYP DMS2 ED 6 TOP TP U V W ERR TH 3 5 1 6 4 2 A1 A2 21 22 KZ 4 3 2 1 3 5 1 6 4 2 21 22 Elektronick brzda PE PE U 3 4 1 2 U V V W W N N 3x400 V 5 IN DMS2 ZPR TERM ON OFF A B PROFIBUS A B...

Страница 34: ...MS2 TORK OTV ZAV STOP LCD displej 2x12 znak DMS2 S VYP DMS2 D 5 TOP TP U V W ERR V stup PE PE U 3 4 1 2 U V V W W N N 3x400V 6 E0033 M3 U2 W2 V2 U1 W1 V1 TH F R Elektronick 4 2 1 3 6T3 4T2 2T1 brzda 5...

Страница 35: ...1 2 W W N N 5 IN DMS2 ZPR TERM ON OFF A B PROFIBUS A B OUT U2 U1 Z2 Z1 M1 C C 1 3 2 4 KZ A1 5 A2 6 1 3 5 2 6 4 KO A1 A2 TH E0009 COM E0009 Example of wiring diagram of electronics DMS2 Profibus in ve...

Страница 36: ...9 280 9 1TZ9002 0CC3 0 25 860 0 98 2 2 25 x x R x N P ED MONED MOPED 200 270 15 100 200 270 15 1TZ9002 0CB3 0 37 1350 1 08 3 2 26 x x S x N P ED MONED MOPED 200 300 25 300 25 1TZ9002 0CB6 0 55 1365 1...

Страница 37: ...00 16 1TZ9002 1BD2 1 5 700 4 7 3 5 97 x x 0 x N P ED MONED MOPED 470 610 25 250 470 610 25 1TZ9002 0EC4 1 1 925 3 15 3 8 90 5 2 0 3 3 x x 1 x N P ED MONED MOPED 500 720 40 720 40 1TZ9002 1BC2 2 2 940...

Страница 38: ...epartment of ZPA Pe ky a s Mark of actuators filled with oil Other actuators are filled with plastic lubricant Table 2 Electric actuators MODACT MONEDJ basic parameters supply voltage 1 x 230 V 50 Hz...

Страница 39: ...l be set for three position regulation control by signal 4 20 mA Note Version 52 03x xxxxNEDJ is delivered in version 52 03x xxx1NEDJ 52 03x xxx2NEDJ or 52 03x xxx9NEDJ If the actuator has DMS2 ED ele...

Страница 40: ...MONED MONEDJ the switchboard box has threads for bushings 3 x thread M20 x 1 5 1 x thread M25 x 1 5 the bushings are included in the delivery wrapped together part For actuators MODACT MOPED the swit...

Страница 41: ...ed 1x cable bushing for motors of axial dimensions 71 80 90 mm M25 x 1 5 range 9 16 mm Non passable push through holes bushing M32x1 5 range 13 20 mm enclosed 1x cable bushing range 10 14 mm 1x cable...

Страница 42: ...to be made by the customer Modification for rising spindle C A E D B C C Protective ring 3xM4x10 Box lid Sealing gasket Lid d3 d1 d2 d4 52 030 xxxxN 52 031 xxxxN 52 032 xxxxN 52 033 xxxxN 52 034 xxxx...

Страница 43: ...tional value d2 f8 d3 d4 number of threaded holes hmax h1 min 1 25d4 d7 h2 b2 H11 d6 d8 g6 I 4 t2max b3 h9 I 5 d9 H8 I 6 min t3 b4 Js9 125 175 210 300 390 70 100 130 200 230 102 140 165 254 298 M 10 M...

Страница 44: ...31 52 033 52 035 52 032 52 034 d1 d2 f8 d3 d4 number of holes d4 h h2 min A d5 d6 max h1 max l min A d5 l1 min h3 max b1 d7 H9 t1 125 175 210 300 70 100 130 200 102 140 165 254 M 10 M 16 M 20 M 16 4 4...

Страница 45: ...another method of installation is required due to local conditions please consult the manufacturer 11 ATTACHMENTTO A FITTING Place the actuator on the fitting so that the output shaft fits dependably...

Страница 46: ...e sure that no phase has been discontinued If a slide valve has jammed and cannot be released even by the handwheel the actuator should be dismantled and the jamming should be mechanically removed Cau...

Страница 47: ...405052737414 of the fitting Rubber copper 40x52x7 SN 029401 0 2 Sealing of output shaft 2327352066 in the power gear box Rubber copper 16x28x7 SN 029401 0 1 Sealing of handwheel shaft 2327352022 Gask...

Страница 48: ...cover 2327311043 Sealing ring 200x3 PN 029281 2 1 Packing between the control box 2327311044 and the power gear box Rubber copper 80x100x13 SN 029401 0 1 Sealing of output shaft in the control box 232...

Страница 49: ...et 224611130 1 Hole cover gasket 405052713614 for the rising spindle of fitting Rubber copper 105x130x13 SN 029401 0 2 Sealing of output shaft 2327352109 in the power gear box Rubber copper 30x50x12 S...

Страница 50: ...n sensor multi revolution DMS2 ED S 39620001 Torque sensor DMS2 TORK 39620003 common for DMS2 ED and DMS2 Analog module DMS ED CPT 39620004 back signal 4 20 mA and software blocked regulator Display D...

Страница 51: ...i turn actuators MODACT MO EEx MOED EEx Explosion proof electric multi turn actuators MODACT MOA Electric multi turn actuators for nuclear power stations application outside containment MODACT MOA OC...

Страница 52: ...tel 420 321 785 141 9 fax 420 321 785 165 420 321 785 167 e mail zpa zpa pecky cz ZPA Pe ky a s t 5 kv tna 166 289 11 PE KY Czech Republic www zpa pecky cz...

Отзывы: