36

Type 

marking

W

orking 

str

oke

[re

vol.]

Type 

of 

 

lubricant

Moment 

[Nm]

Adjusting 

speed [1/min]

Electric 

motor

P

o

wer

[kW]

Type

RPM

[1/min]

I n

 (400 

V) 

[A]

I Z

I  

W

eight

[kg]

Tripping

Star

ting

basic

Type 

No.

1

 2

 3

 4

 5

ad

ditional

10

 

MONED 

(MOPED) 

40/135-7

 

 

 

135

 

 

 

1TZ9002-0CD2

 

0,09

 

635

 

0,53

 

1,8

 

28

 

 

x

 x

 V

 x

 N(P)ED

 

MONED 

(MOPED) 

40/220-9

 

 

 

220

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

26

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

40/135-15

 

 

 

135

 

15

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

26

 

 

x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

40/100-25

 

 

20 

– 

40

 

100

 

25

 

 

 

1TZ9002-0CB2

 

0,25

 

1365

 

0,80

 

3,0

 

24

 

 

x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

40/60-40

 

 

 

60

 

40

 

 

 

1TZ9002-0CB2

 

0,25

 

1365

 

0,80

 

3,0

 

24

 

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

40/95-50

 

 

 

95

 

50

 

 

 

1TZ9002-0CA2

 

0,37

 

2755

 

1,06

 

3,4

 

26

 

 

x

 x

 4

 x

 N(P)ED

 

MONED 

(MOPED) 

40/60-80

 

 

 

60

 

80

 

 

 

1TZ9002-0CA2

 

 0,37

 

2755

 

1,06

 

3,4 

 

26

 

 

x

 x

 5

 x

 N(P)ED

 

MONED 

(MOPED) 

80/135-7

 

 

 

135

 

 

 

1TZ9002-0CD2

 

0,09

 

635

 

0,53

 

1,8

 

28

 

 

x

 x

 k

 x

 N(P)ED

 

MONED 

(MOPED) 

80/220-9

 

 

 

220

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

26

 

 

x

 x

 6

 x

 N(P)ED

 

MONED 

(MOPED) 

80/135-15

 

 

40 

– 

80

 

135

 

15

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

26

 

 

x

 x

 7

 x

 N(P)ED

 

MONED 

(MOPED) 

80/100-25

 

 

 

100

 

25

 

 

 

1TZ9002-0CB2

 

0,25

 

1365

 

0,80

 

3,0

 

24

 

 

x

 x

 8

 x

 N(P)ED

 

MONED 

(MOPED) 

80/104-40

 

 

 

104

 

40

 

– 

1980

 

 

1TZ9002-0CB3

 

0,37

 

1350

 

1,08

 

3,2

 

26

 

x

 x

 9

 x

 N(P)ED

 

MONED 

(MOPED) 

70/95-50

 

 

40 

– 

70

 

95

 

50

 

 

 

1TZ9002-0CA2

 

0,37

 

2755

 

1,06

 

3,4

 

26

 

connecting 

dimension

 

x

 x

 A

 x

 N(P)ED

 

MONED 

(MOPED) 

70/90-80

 

 

 

90

 

80

 

 

 

1TZ9002-0CA3

 

0,55

 

2750

 

1,46

 

3,7

 

25

 

F10

 

x

 x

 B

 x

 N(P)ED

 

MONED 

(MOPED) 

125/160-7

 

 

 

160

 

 

 

1TZ9002-0CD3

 

0,12

 

625

 

0,82

 

2,0

 

26

 

 

x

 x

 L

 x

 N(P)ED

 

MONED 

(MOPED) 

125/220-9

 

 

80 

– 

125

 

220

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

26

 

 

x

 x

 C

 x

 N(P)ED

 

MONED 

(MOEDP)125/170-15

 

 

 

170

 

15

 

 

 

1TZ9002-0CC3

 

0,25

 

860

 

0,98

 

2,2

 

25

 

 

x

 x

 D

 x

 N(P)ED

 

MONED 

(MOPED) 

125/165-25

 

 

 

165

 

25

 

 

 

1TZ9002-0CB3

 

0,37

 

1350

 

1,08

 

3,2

 

26

 

 

x

 x

 E

 x

 N(P)ED

 

MONED 

(MOPED) 

115/150-50

 

 

80 

– 

115

 

150

 

50

 

 

 

1TZ9002-0CA3

 

0,55

 

2750

 

1,46

 

3,7

 

25

 

 

x

 x

 H

 x

 N(P)ED

 

MONED 

(MOPED) 

200/280-9

 

 

 

280

 

 

 

1TZ9002-0CC3

 

0,25

 

860

 

0,98

 

2,2

 

25

 

 

x

 x

 R

 x

 N(P)ED

 

MONED 

(MOPED) 

200/270-15

 

 

100 

– 

200

 

270

 

15

 

 

 

1TZ9002-0CB3

 

0,37

 

1350

 

1,08

 

3,2

 

26

 

 

x

 x

 S

 x

 N(P)ED

 

MONED 

(MOPED) 

200/300-25

 

 

 

300

 

25

 

 

 

1TZ9002-0CB6

 

0,55

 

1365

 

1,62

 

3,6

 

27

 

 

x

 x

 T

 x

 N(P)ED

 

MONED 

(MOPED) 

140/180-50

 

 

100 

– 

140

 

180

 

50

 

 

 

1TZ9002-0CA6

 

0,75

 

2780

 

1.81

 

4,5

 

26

 

 

x

 x

 U

 x

 N(P)ED

 

MONED 

(MOPED) 

95/125-7

 

 

63 

– 

95

 

125

 

 

 

1TZ9002-0CD2

 

0,09

 

635

 

0,53

 

1,8

 

49

 

 

x

 x

 C

 x

 N(P)ED

 

MONED 

(MOPED) 

100/210-9

 

 

 

210

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

49

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

100/185-15

 

 

 

185

 

15

 

 

 

1TZ9002-0CC3

 

0,25

 

860

 

0,98

 

2,2

 

49

 

 

x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

100/130-25

 

 

 

130

 

25

 

 

 

1TZ9002-0DC2

 

0,37

 

915

 

1,23

 

2,7

 

41

 

 

x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

100/165-40

 

 

63 

– 

100

 

165

 

40

 

 

 

1TZ9002-0DB2

 

0,55

 

1385

 

1,44

 

3,7

 

41

 

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

100/140-63

 

 

 

140

 

63

 

 

 

1TZ9002-0DB3

 

0,75

 

1385

 

1,85

 

3,6

 

42

 

 

x

 x

 4

 x

 N(P)ED

 

MONED 

(MOPED) 

100/200-80

 

 

 

200

 

80

 

 

 

1TZ9002-0DA3

 

1,1

 

2840

 

2,45

 

5,7

 

43

 

 

x

 x

 E

 x

 N(P)ED

 

MONED 

(MOPED)100/140-100

 

 

 

140

 

100

 

– 

1400

 

 

1TZ9002-0EB0

 

1,1

 

1405

 

2,5

 

4,5

 

50

 

 

x

 x

 5

 x

 N(P)ED

 

MONED 

(MOPED)100/165-145

 

 

 

165

 

145

 

 

 

1TZ9002-0EA0

 

1,5

 

2835

 

3,3

 

5,5

 

51

 

x

 x

 F

 x

 N(P)ED

 

MONED 

(MOPED) 

125/160-7

 

 

100 

– 

125

 

160

 

 

 

1TZ9002-0CD3

 

0,12

 

625

 

0,82

 

2,0

 

49

 

connecting 

dimension

 

x

 x

 D

 x

 N(P)ED

 

MONED 

(MOPED) 

160/210-9

 

 

 

210

 

 

 

1TZ9002-0CC2

 

0,18

 

875

 

0,85

 

2,0

 

49

 

F14

 

x

 x

 6

 x

 N(P)ED

 

MONED 

(MOPED) 

150/200-16

 

 

 

200

 

16

 

 

 

1TZ9002-0DC2

 

 0,37

 

 915 

 

1,23 

 

2,7 

 

50

 

 

x

 x

 7

 x

 N(P)ED

 

MONED 

(MOPED) 

160/208-25 

 

 

 

208 

 

25 

 

 

 

1TZ9002-0DC3 

 

0,55 

 

900 

 

1,68 

 

2,7 

 

42

 

 

x

 x

 8

 x

 N(P)ED

 

MONED 

(MOPED) 

160/225-40 

 

 

100 

– 

160

 

225 

 

40 

 

 

 

1TZ9002-0DB3 

 

075 

 

1385 

 

1,85 

 

3,6 

 

42

 

 

x

 x

 9

 x

 N(P)ED

 

MONED(MOPED) 

160/330-65 

 

 

 

330 

 

65 

 

 

 

1TZ9002-0EB4 

 

1,5 

 

1410

 

 3,35 

 

4,7

 

 54 

 

 

x

 x

 A

 x

 N(P)ED

 

MONED 

(MOPED) 

160/275-80 

 

 

 

275 

 

80 

 

 

 

1TZ9002-0EA0 

 

1,5

 

 2835 

 

3,3 

 

5,5 

 

46

 

 

 x

 x

 H

 x

 N(P)ED

 

MONED 

(MOPED)160/215-100

 

 

  

215 

 

100 

 

 

 

1TZ9002-0EB4 

 

1,5 

 

1410

 

 3,35

 

 4,7

 

 54 

 

 

x

 x

 B

 x

 N(P)ED

 

MONED 

(MOPED)160/280-130 

 

 

 

280 

 

130 

 

 

 

1TZ9002-0EA4 

 

2,2 

 

2855

 

 4,7 

 

6,5

 

 54

 

 

 x

 x

 J

 x

 N(P)ED

 

 

  

 

 

 

 

 

 

MONED 

(MOPED) 

245/340-7 

 

 

160 

– 

245 

 

340 

 

 

 

 

1TZ9002-0DD3 

 

0,25

 

 680 

 

1,03

 

 2,6 

 

52

 

 

x

 x

 6

 x

 N(P)ED

 

MONED 

(MOPED) 

230/300-9 

 

 

160 

– 

230

  

300

 

 9 

 

 

 

1TZ9002-0DC2 

 

0,37 

 

915 

 

1,23

 

 2,7

 

 50 

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

230/300-16 

 

 

 

300 

 

16 

 

 

 

1TZ9002-0DC3 

 

0,55 

 

900 

 

1,68

 

 2,7

 

 52 

 

 

x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

250/325-25 

 

 

160 

– 

250

  

325 

 

25 

 

 

 

1TZ9002-0EC0 

 

0,75

 

 940 

 

2,3 

 

3,8 

 

45 

 

 

x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

250/325-40 

 

 

 

325

 

40 

 

 

 

1TZ9002-0EB0 

 

1,1 

 

1405

 

 2,5

 

 4,5 

 

45 

 

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

230/300-70 

 

 

160 

– 

230 

 

300 

 

70 

 

 

 

1TZ9002-0EB4 

 

1,5 

 

1410 

 

3,35 

 

4,7

 

 54

 

 

 x

 x

 4

 x

 N(P)ED

 

MONED 

(MOPED) 

250/420-80 

 

 

160 

– 

250 

 

420 

 

80 

 

 

 

1TZ9002-0EA4 

 

2,2 

 

2855 

 

4,7

 

 6,5 

 

49

 

 

 x

 x

 5

 x

 N(P)ED

 

MONED 

(MOPED)200/260-145

 

 

 160 

– 

200 

 

260 

 

145

 

– 

1400

 

 

 1TZ9002-0EA4 

 

2,2

 

 2855

 

 4,7 

 

6,5 

 

49 

 

x

 x

 7

 x

 N(P)ED

 

MONED 

(MOPED) 

400/640-7 

 

 

230 

– 

400 

 

640

 

 7 

 

 

 

1TZ9002-0ED4 

 

0,55 

 

675 

 

1,58 

 

3,0

 

 55

 

connecting 

dimension

 

 x

 x

 E

 x

 N(P)ED

 

MONED 

(MOPED) 

370/480-10 

 

 

230 

– 

370

 

 480 

 

10 

 

 

 

1TZ9002-0DC3 

 

0,55 

 

900 

 

1,68 

 

2,7 

 

53 

 

F14

 

x

 x

 F

 x

 N(P)ED

 

MONED 

(MOPED) 

400/740-16

 

 

 

740 

 

16

 

 

 

 1TZ9002-0EC4 

 

1,1 

 

925 

 

3,15

 

 3,8 

 

55 

 

 

x

 x

 H

 x

 N(P)ED

 

MONED 

(MOPED) 

400/520-25

 

 

230 

– 

400

 

 520 

 

25 

 

 

 

1TZ9002-0EC4

 

 1,1

 

 925 

 

3,15 

 

3,8 

 

48

 

 

 x

 x

 J

 x

 N(P)ED

 

MONED 

(MOPED) 

400/510-40 

 

 

 

510 

 

40 

 

 

 

1TZ9002-0EB4 

 

1,5 

 

1410 

 

3,35

 

 4,7

 

 48 

 

 

x

 x

 K

 x

 N(P)ED

 

MONED 

(MOPED) 

400/520-70 

 

 

 

520 

 

70 

 

 

 

1TZ9001-0EB6 

 

2,2 

 

1425 

 

4,65

 

 6,1

 

 49

 

 

 x

 x

 L

 x

 N(P)ED

 

MONED 

(MOPED) 

320/420-140 

 

 

230 

– 

320 

 

420 

 

140 

 

 

 

1TZ9001-0EA6 

 

3,0 

 

2895 

 

6,0 

 

7,9 

 

49

 

 

x

 x

 M

 x

 N(P)ED

 

MONED 

(MOPED) 

500/800-16 

 

 

250 

– 

500 

 

800 

 

16

 

   

 

1TZ9002-1BD2 

 

1,5 

 

700 

 

4,7

 

 3,5 

 

97

 

  

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

470/610-25 

 

 

250 

– 

470

 

 610 

 

25 

 

 

 

1TZ9002-0EC4 

 

1,1

 

 925

 

 3,15 

 

3,8 

 

90

 

 x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

500/720-40

 

 

 

720 

 

40 

 

 

 

1TZ9002-1BC2 

 

2,2 

 

940 

 

5,7 

 

4,6 

 

93 

 

connecting 

dimension

 

x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

500/670-63 

 

 

250 

– 

500

 

670 

 

63

 

 

 

 1TZ9002-1AB5 

 

3,0 

 

1425

 

 6,3 

 

5,4

 

 90

 

F16

 

 x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

500/770-100 

 

 

 

770 

 

100 

 

 

 

1TZ9002-1AB6 

 

4,0 

 

1435 

 

8,6 

 

5,8 

 

97 

 

 

x

 x

 4

 x

 N(P)ED

 

MONED 

(MOPED) 

630/900-16

 

 

 

900 

 

16 

 

 

 

1TZ9002-1BD2 

 

1,5 

 

700 

 

4,7 

 

3,5 

 

99

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

630/1300-22 

 

 

320 

– 

630

 

1300 

 

22 

 

 

 

1TZ9002-1BC2

 

 2,2 

 

940 

 

5,7 

 

4,6 

 

103 

 

 

x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

630/830-35 

 

 

 

830 

 

35 

 

 

 

1TZ9002-1AB4 

 

2,2

 

 1425 

 

4,9 

 

5,1 

 

97 

 

x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

630/900-63 

 

 

 

900 

 

63 

 

– 

1080

 

 

1TZ9002-1BB2 

 

4,0 

 

1435 

 

8,4

 

 6,1 

 

97

 

connecting 

dimension

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

1000/1300-22

  

 

1300 

 

22 

 

 

 

1TZ9002-1BC2 

 

2,2 

 

940 

 

5,7 

 

4,6 

 

102 

 

F16

 

x

 x

 6

 x

 N(P)ED

 

MONED 

(MOPED) 

1000/1400-35 

  

500 

– 

1000

 

1400 

 

35 

 

 

 

1TZ9002-1BB2 

 

4,0

 

 1435 

 

8,4

 

 6,1 

 

105

 

 

 x

 x

 7

 x

 N(P)ED

  

MONED 

(MOPED) 

1000/1500-63 

  

 

1500 

 

63 

 

 

 

1TZ9002-1BB6 

 

5,5 

 

1420 

 

11,6 

 

5,8 

 

109 

 

 

x

 x

 9

 x

 N(P)ED

 

MONED 

(MOPED) 

1250/1780-45 

  

630 

– 

1250

  

1780 

 

45 

 

 

 

1TZ9002-1CC3 

 

5,5 

 

955 

 

12,7 

 

5,7 

 

211

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

1250/1650-70 

  

 

1650 

 

70 

 

 

 

1TZ9002-1CB2 

 

7,5 

 

1450 

 

15,4 

 

6,6 

 

206

 

 x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

900/1170-100

  

 630 

– 

900 

 

1170 

 

100 

 

 

 

1TZ9002-1CB2 

 

7,5 

 

1450 

 

15,4 

 

6,6 

 

206

 

connecting 

dimension

 

 x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

1800/2400-70 

  

1000 

– 

1800 

 

2400 

 

70 

 

 

 

1TZ9002-1CB6 

 

11 

 

1450 

 

21,5 

 

7,2

 

 217 

 

F25

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED)1250/1650-100 

 

630 

– 

1250 

 

1650 

 

100 

 

 

 

1TZ9002-1CB6 

 

11 

 

1450 

 

21,5

 

 7,2 

 

217 

 

 

x

 x

 4

 x

 N(P)ED

 

MONED 

(MOPED) 

2500/3850-20 

  

1000 

– 

2500 

 

3850 

 

20

 

 

 

1TZ9002-1CC3 

 

5,5 

 

955 

 

12,7 

 

5,7 

 

309

 

 

x

 x

 0

 x

 N(P)ED

 

MONED 

(MOPED) 

2500/3600-30 

  

 

3600 

 

30 

 

 

 

1TZ9002-1CB2 

 

7,5 

 

1450

 

 15,4 

 

6,6

 

 304

 

 x

 x

 1

 x

 N(P)ED

 

MONED 

(MOPED) 

2000/2600-40 

  

1000 

– 

2000 

 

2600 

 

40 

 

– 

460

 

 

1TZ9002-1CB2 

 

7,5 

 

1450

 

 15,4

 

 6,6

 

 304

 

connecting 

dimension

 

 x

 x

 2

 x

 N(P)ED

 

MONED 

(MOPED) 

3900/5100-30 

  

2000 

– 

3900 

 

5100 

 

30 

 

 

 

1TZ9002-1CB6 

 

11 

 

1450 

 

21,5

 

 7,2 

 

315 

 

F30

 

x

 x

 3

 x

 N(P)ED

 

MONED 

(MOPED) 

2800/3600-40 

  

1600 

– 

2800

 

 3600 

 

40 

 

 

 

1TZ9002-1CB6 

 

11 

 

1450

 

 21,5

 

 7,2 

 

315 

 

 

x

 x

 4

 x

 N(P)ED

 

Tab

le 

– 

Electric 

actuator

MOD

A

CT 

MONED

, MOPED 

– 

basic 

parameter

s

With 

1TZ9002 

(1LE1002)

 electr

ic 

motors 

– 

supply 

voltage 

230/400 

V, 

50 

Hz, 

protection

 IP 

55 

(MOD

A

CT 

MONED),

 IP 

67 

(MOD

A

CT 

MOPED)

Содержание MODACT MONED

Страница 1: ...10 18 MOUNTING INSTRUCTIONS Electric Multi turn Actuators Type numbers 52 030 52 036 Type numbers 52 030 52 032...

Страница 2: ...ZPA Pe ky a s is certified company in accordance with ISO 90001 as amended...

Страница 3: ...eric precipitations under an angle up to 60 from the vertical is prevented The electric actuator must be installed in a place where cooling air has a free access Minimum distance from a wall for acces...

Страница 4: ...orque Mv According to SN EN 60 034 1 the actuators can also be operated in the S4 mode interrupted operation with acceleration intervals The load factor N N R shall be maximum 25 per cent the longest...

Страница 5: ...10 15 50 Hz 2 3 x 220 380 V 10 15 50 Hz 3 5 MODACT MONEDJ 1 x 230 V 10 15 50 Hz 2 1 x 220 V 10 15 50 Hz 3 5 or according to data on the rating plate Actuators designed to operate at another voltage an...

Страница 6: ...he valve Torque limit switches in the actuator are set and work when the actuator is under voltage When using the manual control ie actuator is controlled mechanically the torque limit switches doesn...

Страница 7: ...nal board for connection to external circuits This terminal board uses screw terminals allowing conductors with a maximum cross section 4 mm2 to be connected Access to the terminal board is obtained a...

Страница 8: ...e gearing the central wheel of the differential gear located in the load bearing box of the electric actuator force gear In motor control the crown wheel of the epicyclic differential is held in const...

Страница 9: ...onnection of computer for setting and diagnostics Torque unit Source unit electronic power supply user s terminal board connection of power supply and control signals 2 torque relays 2 position relays...

Страница 10: ...indow Parameters of the setting program column Access the word NO designates parameters that cannot be changed by the user change of these parameters is blocked Relay READY It usually signalizes error...

Страница 11: ...does not react to the set position and can only be stopped by the torque relay In controlling from menu MOTOR no torque may be induced The torque must be left manually If during adjustment the torque...

Страница 12: ...button MENU for at least 2 s The setting menu will also be left in case that no push button is pressed within 1 minute MENU 1 Setting of tripping torques After entering the menu by means of push butto...

Страница 13: ...risk of damaging the actuator by wrong wiring In controlling the actuator from program DMS2 its run is stopped when any torque is induced Working torque Check and if necessary set the value of working...

Страница 14: ...1 10 Output of position signal 4 20 mA 20 4 mA Function READY combined error Note Signal READY is brought out as contact of the relay on the terminal board If the state ERROR or WARNING is not detect...

Страница 15: ...industrial bus does not communicate or not added in parameter CAN of configuration 26 CAN X Error of bus CAN short circuit interruption only sensor communicates 27 Fieldbus activity X Connection to in...

Страница 16: ...MI DAL PO 16 PZ 19 15 4 17 MZ 12 3 13 11 RU OR 5V M stn ovl d n M D READY 6 5 O Z TOP 1 2 N 8 7 N F160mA N polohy 2x L COMM Analogov modul L mA Pas vn v stup Aktivn v stup D lkov povoleno zav rej Mot...

Страница 17: ...10 MO MENU P C O Sn ma momentu Sn ma Zdrojov deska 30 29 N U 4 6 C NO C 24 26 27 NO NC NO C NC NO NC C 20 22 21 17 16 19 18 NC C C M 13 12 3 W1 V1 15 W2 V2 1 5 U1 U2 3 2 23 6 5 3 4 PE N U PE 2 42 L CO...

Страница 18: ...p 3x400 V D lkov povoleno D lkov D lkov M3 U1 W1 V1 E0002 V proveden bez m stn ho ovl d n se propojka ze svorky U zapoj na svorku 2 otev rej zav rej Example of wiring diagram Substitution of electro m...

Страница 19: ...W N N polohy 2x PE IN IN L COMM Analogov modul L mA Pas vn v stup Aktivn v stup 4 20mA 3x400 V U2 W2 V2 U1 W1 V1 TH E0003 U proveden bez m stn ho ovl d n se propojka ze svorky U zapoj na svorku 2 Sour...

Страница 20: ...2 U2 L Analogov modul COMM L IN IN PE 2x polohy N N W W V V F160mA U N 7 8 N 2 1 TOP Z O 5 6 READY D M M stn ovl d n 5V OR RU 11 13 3 12 MZ 17 4 15 19 PZ 16 PO MI DAL T P 23 18 22 21 24 SO SZ U 20 COM...

Страница 21: ...switching of electric motor EM0004 ZBT Torque sensor Position sensor Analog module Active output Passive output Note Here contacts of relays MO MZ SO SZ are shown with power supply switched off with p...

Страница 22: ...wiring diagram of electronics DMS2 ED in version Control with contact less switching of electric motor with connector connection EM0043K ZBT Torque sensor Position sensor Analog module Passive output...

Страница 23: ...terminals for connecting external control signals input of signal SAFE information on external failure relay total of five four signalling can be set for reporting of position torque or other operati...

Страница 24: ...k and if necessary change other parameters Control signal 4 20 mA 20 4mA 0 20 mA 20 0 mA 2 position Bus Insensitivity 1 1 0 Function SAFE Open Close Stop To position Active SAFE O V 230 V Time of bloc...

Страница 25: ...ly Overview of MENU Name Parameter value Meaning 1 JAZ LANGUAGE CESKY Menu LANGUAGE ENGLISH 2 POLOHA O Z POL OTEVR End limit position Open or Closed POL ZAVRENO 3 KALIBRACE SPUSTIT Starting of autocal...

Страница 26: ...rminate the setting regime Setting end limit positions by means of push buttons of local control Shift the change over switch LOCAL REMOTE to position OFF Keep pressing push button STOP to enter the s...

Страница 27: ...27 Connector to connect local display not used here Terminal board of DMS2 Analog Terminal board of DMS2 Profibus...

Страница 28: ...th suffix par in the example in the figure the file 52 030 par is created in the directory Flash The file can serve as a back up for the case that it will be necessary to replace the position sensor i...

Страница 29: ...30V U test TH 3 5 1 6 4 2 A1 A2 21 22 A1 A2 KZ 3 5 1 6 4 2 21 22 PE PE U N 8 7 N U V V W W N N 3x400 V RO Aktivn Pas vn v stup KO M3 U2 W2 V2 U1 W1 V1 E0006 22 21 20 26 25 24 23 SAFE N230V N24 48V N23...

Страница 30: ...SAFE DMS2 D RZ TOP TP U V W ERR RE1 RE2 RE3 RE4 PE IN IN L COMM L mA v stup v stup 0 4 20mA U 60V 60 230V U zav rej otev rej U 60V 60 230V U test TH 3 5 1 6 4 2 A1 A2 21 22 A1 A2 KZ 3 5 1 6 4 2 21 22...

Страница 31: ...rej U 60V 60 230V U test PE PE U 3 4 1 2 U V V W W N N 3x400 V 6 Aktivn v stup Pas vn v stup E0031 M3 U2 W2 V2 U1 W1 V1 TH F R Elektronick 4 2 1 3 6T3 4T2 2T1 brzda 5L3 3L2 1L1 0V 12V RZ RO 22 21 20...

Страница 32: ...v stup 0 4 20mA U 60V 60 230V U Zav rej Otev rej U 60V 60 230V U Test PE PE 3 4 1 2 W W N N 5 RC COMM RNC RNO Aktivn Pas vn U2 U1 Z2 Z1 M1 C C 1 3 2 4 KZ A1 5 A2 6 1 3 5 2 6 4 KO A1 A2 TH E0007 COM OP...

Страница 33: ...12 znak DMS2 S VYP DMS2 ED 6 TOP TP U V W ERR TH 3 5 1 6 4 2 A1 A2 21 22 KZ 4 3 2 1 3 5 1 6 4 2 21 22 Elektronick brzda PE PE U 3 4 1 2 U V V W W N N 3x400 V 5 IN DMS2 ZPR TERM ON OFF A B PROFIBUS A B...

Страница 34: ...MS2 TORK OTV ZAV STOP LCD displej 2x12 znak DMS2 S VYP DMS2 D 5 TOP TP U V W ERR V stup PE PE U 3 4 1 2 U V V W W N N 3x400V 6 E0033 M3 U2 W2 V2 U1 W1 V1 TH F R Elektronick 4 2 1 3 6T3 4T2 2T1 brzda 5...

Страница 35: ...1 2 W W N N 5 IN DMS2 ZPR TERM ON OFF A B PROFIBUS A B OUT U2 U1 Z2 Z1 M1 C C 1 3 2 4 KZ A1 5 A2 6 1 3 5 2 6 4 KO A1 A2 TH E0009 COM E0009 Example of wiring diagram of electronics DMS2 Profibus in ve...

Страница 36: ...9 280 9 1TZ9002 0CC3 0 25 860 0 98 2 2 25 x x R x N P ED MONED MOPED 200 270 15 100 200 270 15 1TZ9002 0CB3 0 37 1350 1 08 3 2 26 x x S x N P ED MONED MOPED 200 300 25 300 25 1TZ9002 0CB6 0 55 1365 1...

Страница 37: ...00 16 1TZ9002 1BD2 1 5 700 4 7 3 5 97 x x 0 x N P ED MONED MOPED 470 610 25 250 470 610 25 1TZ9002 0EC4 1 1 925 3 15 3 8 90 5 2 0 3 3 x x 1 x N P ED MONED MOPED 500 720 40 720 40 1TZ9002 1BC2 2 2 940...

Страница 38: ...epartment of ZPA Pe ky a s Mark of actuators filled with oil Other actuators are filled with plastic lubricant Table 2 Electric actuators MODACT MONEDJ basic parameters supply voltage 1 x 230 V 50 Hz...

Страница 39: ...l be set for three position regulation control by signal 4 20 mA Note Version 52 03x xxxxNEDJ is delivered in version 52 03x xxx1NEDJ 52 03x xxx2NEDJ or 52 03x xxx9NEDJ If the actuator has DMS2 ED ele...

Страница 40: ...MONED MONEDJ the switchboard box has threads for bushings 3 x thread M20 x 1 5 1 x thread M25 x 1 5 the bushings are included in the delivery wrapped together part For actuators MODACT MOPED the swit...

Страница 41: ...ed 1x cable bushing for motors of axial dimensions 71 80 90 mm M25 x 1 5 range 9 16 mm Non passable push through holes bushing M32x1 5 range 13 20 mm enclosed 1x cable bushing range 10 14 mm 1x cable...

Страница 42: ...to be made by the customer Modification for rising spindle C A E D B C C Protective ring 3xM4x10 Box lid Sealing gasket Lid d3 d1 d2 d4 52 030 xxxxN 52 031 xxxxN 52 032 xxxxN 52 033 xxxxN 52 034 xxxx...

Страница 43: ...tional value d2 f8 d3 d4 number of threaded holes hmax h1 min 1 25d4 d7 h2 b2 H11 d6 d8 g6 I 4 t2max b3 h9 I 5 d9 H8 I 6 min t3 b4 Js9 125 175 210 300 390 70 100 130 200 230 102 140 165 254 298 M 10 M...

Страница 44: ...31 52 033 52 035 52 032 52 034 d1 d2 f8 d3 d4 number of holes d4 h h2 min A d5 d6 max h1 max l min A d5 l1 min h3 max b1 d7 H9 t1 125 175 210 300 70 100 130 200 102 140 165 254 M 10 M 16 M 20 M 16 4 4...

Страница 45: ...another method of installation is required due to local conditions please consult the manufacturer 11 ATTACHMENTTO A FITTING Place the actuator on the fitting so that the output shaft fits dependably...

Страница 46: ...e sure that no phase has been discontinued If a slide valve has jammed and cannot be released even by the handwheel the actuator should be dismantled and the jamming should be mechanically removed Cau...

Страница 47: ...405052737414 of the fitting Rubber copper 40x52x7 SN 029401 0 2 Sealing of output shaft 2327352066 in the power gear box Rubber copper 16x28x7 SN 029401 0 1 Sealing of handwheel shaft 2327352022 Gask...

Страница 48: ...cover 2327311043 Sealing ring 200x3 PN 029281 2 1 Packing between the control box 2327311044 and the power gear box Rubber copper 80x100x13 SN 029401 0 1 Sealing of output shaft in the control box 232...

Страница 49: ...et 224611130 1 Hole cover gasket 405052713614 for the rising spindle of fitting Rubber copper 105x130x13 SN 029401 0 2 Sealing of output shaft 2327352109 in the power gear box Rubber copper 30x50x12 S...

Страница 50: ...n sensor multi revolution DMS2 ED S 39620001 Torque sensor DMS2 TORK 39620003 common for DMS2 ED and DMS2 Analog module DMS ED CPT 39620004 back signal 4 20 mA and software blocked regulator Display D...

Страница 51: ...i turn actuators MODACT MO EEx MOED EEx Explosion proof electric multi turn actuators MODACT MOA Electric multi turn actuators for nuclear power stations application outside containment MODACT MOA OC...

Страница 52: ...tel 420 321 785 141 9 fax 420 321 785 165 420 321 785 167 e mail zpa zpa pecky cz ZPA Pe ky a s t 5 kv tna 166 289 11 PE KY Czech Republic www zpa pecky cz...

Отзывы: