Cleaning
the door
After each smo-
othing process
or when needed
Soak a piece of cloth
in isopropyl alcohol,
acetone or butanone
(MEK), and thoroughly
clean the door. Focus
on the point of contact
between the door
and the gasket
- gloves,
- a piece of cloth,
- chemical or degre-
asing substance,
- safety glasses
Cleaning
the gasket
Before each
smoothing
process
Soak a piece of cloth
in isopropyl alcohol,
acetone or butanone
(MEK), and thoroughly
clean the gasket, direc-
ting the cloth along
the gasket’s profile.
The gasket should not
be cleaned with the
use of sharp tools.
- gloves,
- a piece of cloth,
- chemical or degre-
asing substance,
- safety glasses
Adding the
solvent
Right after
receiving a
notification
Follow the proce-
dure of adding the
solvent (
page 31
)
- gloves,
- a bottle with a tube,
- acetone or
butanone (MEK),
- safety glasses
Changing
the solvent
When needed or
once a month
Follow the procedu-
re of changing the
solvent (
page 33
)
- gloves,
- a bottle for the
remaining solvent,
- safety glasses
Cleaning the
drain tube
After each smo-
othing process
After cleaning the
solvent tank, use a
brush to clean the tip
of the drain tube to
avoid any blockage
- gloves,
- a piece of cloth,
- a brush,
- chemical or degre-
asing substance,
- safety glasses