English - 43
IB v3.0.0 2021
© 2021 ZES - All rights reserved
Factory reset can be applied to device from here.
Note that: Restart your device in order for the changes made on the page to take effect.
CONTACTOR WELDED MONITORING
A shunt trip behavior is contained in Control boards of the charging station. If a contactor welded
case was occured CN43 connector as shown in below figure starts to apply a PWM signal. If this
connector mounted by a shunt trip device, the fuse blows and the energy is cut off.