According to IEC 61851-1 and EV/ZE Ready requirements, EVC05 EV Charging Station has welded
contactor sensing function, and welded contactor information is provided as a contactor welded
output signal from the control board. To detect welded contact failure for the relays, CN43 connector
output terminals must be used. In case of a welded contact for the relays CN43 connector output
will be 230V AC. The output which has 230V AC should be connected to a shunt trip for RCCB
triggering as shown in the following figure. Connector (CN43) terminals must be connected to a
Shunt trip module. Shunt Trip module is mechanically coupled to RCCB (or MCB) at the fuse box
of the charging station (optionally). The circuitry block diagram that must be used at the fuse box
of the charging station is shown below.
1
2
EVSE
N
L1_W
CN33
230V
FACTORY RESET
You must push the button on HMI board shown in figure below for factory reset. When you hold the
button for 1 seconds, user configuration will be reset to factory configuration.
(e.g OCPP config, Network Config will be back to factory configuration.)
HMI Outputs which may be needed by service
(all necessary connections are generally done as
factory configured)