The charging station has ability to detect the tilt of device by a tilt sensor inside. The user can
change tilt threshold setting as an angle. Tilt threshold is set by default as 30 and can be set by
user between 0-90 degrees.
4.4 - INSTALLATION SETTINGS IN WEB CONFIG UI
User can set AC mains input current values individually for each socket outlet as shown below. For
schuko outlets, maximum current can be set between interval 8-16A. If the user sets maximum
current as 10A and if the EV draws over 10A, charging station automatically stops charging and
gives overcurrent error. For Type2 AC outlets, maximum current can be set as 32A. Because of
OCPP standard, the minimum current should be 6A.
IT network support can be enabled/disabled from Earthing Type Tab in web configuration interface.
If Earthing Type is selected as IT, the protective earth error check is disabled. In webconfiguration
interface, earthing type is “other” by default