English - 33
IB v3.0.0 2021
© 2021 ZES - All rights reserved
1
CN2
EVSE
RL
1
4
2
3
2
If the external relay (RL) is in non-conducting (open), the charging station will not be not be able
to charge the electric vehicle.
You can connect potential free input signals as shown in above circuitry (see figure below).
Load Shedding
Input support can been enabled/disabled from Installation settings If load shedding
Input is selected as enabled, the load shedding Input is active in ACCT. CN44 connector, shown
in below figure, is used for this functionality, if CN44 pins are shorted, current is limited to 8A.
Default value for this option is set as disabled in webconfiguration interface.