1.3.1 Wiring on a spring-cage terminal block

• 

Pull the lever up as far as it will go, then connect the cable (see figure 

).

• 

Return the lever back to its initial position (see image 

).

9 - 10mm

1.4  I  Option connections

Connecting the "Heating priority" and "Remote "On/off" control" options:

•  Before any work inside the appliance, you must cut the appliance’s electricity supply as there is 

a risk of electric shock which may cause material damage, serious injury or even death.

•  Any incorrect connection to terminals 1 to 6 may damage the appliance and cancel its warranty.

•  Under no circumstances should the filtration pump motor be supplied via terminals 5 - 6.

•  When  intervening  on  terminals  1  to  6,  there  is  a  risk  of  electrical  return  current,  injuries, 

material damage and death.

•  Use cables with a section of at least 2x0.75mm² , H07RN-F type and with a diameter between 

8 and 13mm.

•  Use the gland to pass the cables into the appliance. The cables used for the options and the 

power cord must be kept separate (risk of interference) using a collar inside the appliance just 

after the glands.

1.4.1 "Heating priority" option

• 

This function allows the appliance to start filtration (in 5-minute cycles every 120 minutes) in order to detect the 

water temperature and thus activate the filt heating unit to maintain a constant water temperature. The 

filter pump is thus said to be slaved to the heating system. Filtration is kept in operation or activated if the pool 

temperature falls below the desired temperature.

• 

For the connection, connect the filtration timer to terminals 1 - 2 (dry contact, no polarity, maximum intensity 8A).

• 

The "Heating priority" function is activated by default; to deactivate it, set the P50 parameter to "

ON

".

1

2

1- 

2: power for the filtration pump power contactor coil

: filtration timer

: power contactor (tripolar or bipolar) for the filtration system pump motor

: separate cable for the "heating priority" function (not supplied)

: heat pump terminal board

: fuse

EN

Содержание Z550iQ

Страница 1: ...H0673700_REVA 2020 10 More documents on www zodiac com Z550iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...tandards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of...

Страница 3: ...carrying out any operations check that The required input voltage indicated on the appliance information plate corresponds to the mains voltage The mains supply is compatible with the appliance s ele...

Страница 4: ...essures with the consequent risk of severe burns TROUBLESHOOTING All brazing must be carried out by qualified brazers Replacement pipes must always be made of copper in compliance with standard NF EN...

Страница 5: ...3 1 I Winterising 17 3 2 I Maintenance 17 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wiring diagrams 21 Ch...

Страница 6: ...owing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away on brackets Within range of water or mud jets sprays or run off take the effect of the wind into account Ne...

Страница 7: ...djustment valve optional water outlet adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensates fit a 18 pipe on the grooved el...

Страница 8: ...ntry where it is installed The appliance is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker C or D curve for rating see 5 2...

Страница 9: ...nd to pass the cables into the appliance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 4 1 H...

Страница 10: ...on off switch not supplied separate connection cable not supplied When the contact 3 4 is open The device cannot be started in any way The OFF message see image alternates with the current display th...

Страница 11: ...T or ECOSILENCE mode Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more e...

Страница 12: ...blue Cooling mode 1 100 The heat pump is cooling the water 1 50 Heat pump on standby for one of the following reasons inherent to the machine s regulation in normal operation Compressor timer anti sh...

Страница 13: ...valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect th...

Страница 14: ...e previous screen Press several times to return to the main screen where the measured water temperature is displayed 2 4 2 Adjusting the temperature setpoint From the main screen where the measured wa...

Страница 15: ...turning to the setpoint temperature 0 5 C 28 C 27 5 C 28 5 C 30 C Heating green LED Heating green LED Cooling blue LED Temperature setpoint Triggering cancellation threshold for the heating function T...

Страница 16: ...speed HIGH 100 or or or MID 75 LOW 50 The LED strip goes up to HIGH The LED strip fluctuates between LOW MID and HIGH The LED strip fluctuates between LOW and MID Status Heating Objective Quickly incr...

Страница 17: ...ump the Wi Fi signal must be detectable at the place where the appliance is used If this is not the case a technical solution must be provided to amplify the existing signal Rest close to the applianc...

Страница 18: ...tivating the modem s Wi Fi connection is recommended to avoid any risk of the appliance being remotely controlled Do not disconnect the electricity supply when the appliance is running If the electric...

Страница 19: ...onverted to gas If the appliance is not in its defrost cycle this is not normal Switch off and disconnect the appliance immediately and contact your retailer The appliance is not working If there is n...

Страница 20: ...offline J16 connector Reconnect or change the sensor Press E09 ST3 sensor fault defrost sensor Sensor is faulty or offline J14 connector Reconnect or change the sensor Press E10 ST2 sensor fault air i...

Страница 21: ...m E19 Driver compressor communication fault Bad connection between the A1 and A2 boards Check that the CONIN A1 board and AB A2 driver board connectors are correctly connected LED steady red automatic...

Страница 22: ...21 4 4 I Wiring diagrams 4 4 1 Z550iQ MD4 MD5 MD8...

Страница 23: ...22 4 4 2 Z550iQ TD5 TD8 EN...

Страница 24: ...AN HEATER Conveyor resistor GRN YEL Green Yellow HEATER Anti freeze resistor condenser HP High pressure switch J1 Flow switch LED LED electronic board LP Low pressure switch M1 Fan motor M2 Compressor...

Страница 25: ...on A Z550iQ B 50 connector to be glued x2 C Condensate drainage kit 18 D Winterising cap x2 E Winterising cover Heating priority F Technical room kit G Condensation tray H PAC NET cleaning product Inc...

Страница 26: ...l electric current requirement A 9 6 5 12 4 9 5 9 1 6 17 6 7 5 6 3 5 Maximum electric current requirement A 12 5 13 8 6 20 8 Minimum cable section mm 3x2 5 5x2 5 3x6 5x2 5 3G2 5 5G2 5 3G6 5G2 5 Hydrau...

Страница 27: ...26 5 3 I Dimensions and marking Top Bottom Front Rear Grid LED strip User interface Technical access door Pool water inlet Pool water outlet Evaporator Condensates drain EN...

Страница 28: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...

Отзывы: