1.3  I  Electricity supply connections

•  Before any work inside the appliance, you must cut the electricity supply as there is a risk of 

electric shock which may cause material damage, serious injury or even death.

•  Only a qualified and experienced technician is authorised to carry out cabling work within the 

appliance or to replace the power cord.

•  Poorly  tightened  cabling  terminals  can  cause  the  cables  to  overheat  at  the  terminals  and 

create a fire risk. Make sure that the terminal screws are fully tightened. Incorrectly tightened 

terminal screws will cancel the warranty.

•  Do not disconnect the electricity supply when the appliance is running. If the electric power 

supply is interrupted, wait a minute before restoring the power.

•  Means for disconnecting from the mains supply for all poles guaranteeing full disconnection 

in the over-voltage category III must be compliant and incorporated into the wiring.

• 

To access the electrical connection terminal boards:

x2 screws

Unscrew the 3 screws

Slide the door downwards

• 

The heat pump's electrical supply must be provided through a protection and circuit breaking device (not supplied) 

complying with the standards and regulations in force in the country where it is installed.

• 

The appliance is provided for connection to a general power supply with a TT and TN.S neutral regime.

• 

Electrical protection: by circuit breaker (C or D curve) (for rating, see § “5.2  I  Technical data”), with a 30 mA dedicated 

residual-current protection system (circuit breaker or switch).

• 

Additional protection may be required during installation to guarantee the overvoltage category II.

• 

The power supply must correspond to the voltage indicated on the appliance's information plate.

• 

The power cord must be insulated against any cutting or hot elements that may damage or crush it.

• 

The appliance must be correctly connected to a suitable earth/ground circuit.

• 

The electrical connection lines must be fixed.

• 

Use the gland to pass the power cord into the appliance.

• 

Use the power cord (H07RN-F type) adapted for outdoor or buried use (or run the cable into a protection duct) with 

an external diameter of between 13 and 18mm.

• 

We recommend burying the cable at a depth of 50 cm (85 cm under a road or path) in an electrical duct (red ribbed).

• 

If this buried cable meets another cable or pipe (gas, water, etc.), there must be more than 20 cm between them.

• 

Connect the power supply cord to the spring-cage terminal block inside the appliance (see § "1.3.1 I Wiring on a 

spring-cage terminal block").

Information: three-phase model terminal boards

• 

On three phase models, there is no live order to be respected.

Содержание Z550iQ

Страница 1: ...H0673700_REVA 2020 10 More documents on www zodiac com Z550iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...tandards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of...

Страница 3: ...carrying out any operations check that The required input voltage indicated on the appliance information plate corresponds to the mains voltage The mains supply is compatible with the appliance s ele...

Страница 4: ...essures with the consequent risk of severe burns TROUBLESHOOTING All brazing must be carried out by qualified brazers Replacement pipes must always be made of copper in compliance with standard NF EN...

Страница 5: ...3 1 I Winterising 17 3 2 I Maintenance 17 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wiring diagrams 21 Ch...

Страница 6: ...owing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away on brackets Within range of water or mud jets sprays or run off take the effect of the wind into account Ne...

Страница 7: ...djustment valve optional water outlet adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensates fit a 18 pipe on the grooved el...

Страница 8: ...ntry where it is installed The appliance is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker C or D curve for rating see 5 2...

Страница 9: ...nd to pass the cables into the appliance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 4 1 H...

Страница 10: ...on off switch not supplied separate connection cable not supplied When the contact 3 4 is open The device cannot be started in any way The OFF message see image alternates with the current display th...

Страница 11: ...T or ECOSILENCE mode Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more e...

Страница 12: ...blue Cooling mode 1 100 The heat pump is cooling the water 1 50 Heat pump on standby for one of the following reasons inherent to the machine s regulation in normal operation Compressor timer anti sh...

Страница 13: ...valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect th...

Страница 14: ...e previous screen Press several times to return to the main screen where the measured water temperature is displayed 2 4 2 Adjusting the temperature setpoint From the main screen where the measured wa...

Страница 15: ...turning to the setpoint temperature 0 5 C 28 C 27 5 C 28 5 C 30 C Heating green LED Heating green LED Cooling blue LED Temperature setpoint Triggering cancellation threshold for the heating function T...

Страница 16: ...speed HIGH 100 or or or MID 75 LOW 50 The LED strip goes up to HIGH The LED strip fluctuates between LOW MID and HIGH The LED strip fluctuates between LOW and MID Status Heating Objective Quickly incr...

Страница 17: ...ump the Wi Fi signal must be detectable at the place where the appliance is used If this is not the case a technical solution must be provided to amplify the existing signal Rest close to the applianc...

Страница 18: ...tivating the modem s Wi Fi connection is recommended to avoid any risk of the appliance being remotely controlled Do not disconnect the electricity supply when the appliance is running If the electric...

Страница 19: ...onverted to gas If the appliance is not in its defrost cycle this is not normal Switch off and disconnect the appliance immediately and contact your retailer The appliance is not working If there is n...

Страница 20: ...offline J16 connector Reconnect or change the sensor Press E09 ST3 sensor fault defrost sensor Sensor is faulty or offline J14 connector Reconnect or change the sensor Press E10 ST2 sensor fault air i...

Страница 21: ...m E19 Driver compressor communication fault Bad connection between the A1 and A2 boards Check that the CONIN A1 board and AB A2 driver board connectors are correctly connected LED steady red automatic...

Страница 22: ...21 4 4 I Wiring diagrams 4 4 1 Z550iQ MD4 MD5 MD8...

Страница 23: ...22 4 4 2 Z550iQ TD5 TD8 EN...

Страница 24: ...AN HEATER Conveyor resistor GRN YEL Green Yellow HEATER Anti freeze resistor condenser HP High pressure switch J1 Flow switch LED LED electronic board LP Low pressure switch M1 Fan motor M2 Compressor...

Страница 25: ...on A Z550iQ B 50 connector to be glued x2 C Condensate drainage kit 18 D Winterising cap x2 E Winterising cover Heating priority F Technical room kit G Condensation tray H PAC NET cleaning product Inc...

Страница 26: ...l electric current requirement A 9 6 5 12 4 9 5 9 1 6 17 6 7 5 6 3 5 Maximum electric current requirement A 12 5 13 8 6 20 8 Minimum cable section mm 3x2 5 5x2 5 3x6 5x2 5 3G2 5 5G2 5 3G6 5G2 5 Hydrau...

Страница 27: ...26 5 3 I Dimensions and marking Top Bottom Front Rear Grid LED strip User interface Technical access door Pool water inlet Pool water outlet Evaporator Condensates drain EN...

Страница 28: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...

Отзывы: