WARNINGS CONCERNING APPLIANCES CONTAINING R410A REFRIGERANT

• 

Do not discharge R410A fluid into the atmosphere. This is a fluorinated greenhouse 

gas, covered by the Kyoto Protocol, with a Global Warming Potential (GWP) = 2088 

(European regulation EU 517/2014).

• 

In order to comply with the applicable standards and regulations in terms of the 

environment and installation, in particular Decree No. 2015-1790 and/or European 

regulation EU 517/2014, a leak test must be performed on the cooling circuit when 

the appliance is first started and at least once a year. This operation must be carried 

out by a specialist certified to test cooling appliances. 

INSTALLATION AND MAINTENANCE

• 

The appliance may not be installed close to combustible materials, or the air duct 

inlet of an adjacent building.

• 

With some appliances, it is essential to fit a "protection grid"-type accessory if the 

unit is installed in an area with uncontrolled access.

• 

During installation, troubleshooting and maintenance, pipes may not be used as 

steps: the pipe could break under the weight, spilling coolant and possibly causing 

serious burns.

• 

When servicing the appliance, the composition and state of the heat transfer fluid 

must be checked, as well as the absence of any traces of coolant.

WARNINGS ASSOCIATED WITH ELECTRICAL APPLIANCES

• 

The power supply to the appliance must be protected by a dedicated 30 mA Residual 

Current Device (RCD), complying with the standards and regulations in force in the 

country in which it is installed.

• 

Do  not  use  any  extension  lead  when  connecting  the  appliance;  connect  the 

appliance directly to a suitable power supply.

• 

Before carrying out any operations, check that:

 -

The  required  input  voltage  indicated  on  the  appliance  information  plate 

corresponds to the mains voltage;

 -

The  mains  supply  is  compatible  with  the  appliance's  electricity  needs  and  is 

correctly grounded.

• 

In the event of abnormal operation or the release of odours from the appliance, 

turn it off immediately, unplug it from its power supply and contact a professional.

• 

Before  servicing  or  performing  maintenance  on  the  appliance,  check  that  it  is 

powered  off  and  completely  disconnected  from  the  power  supply.  Moreover, 

check  that  the  heating  priority  (where  applicable)  is  deactivated  and  that  any 

other device or accessory connected to the appliance is also disconnected from 

the power supply.

• 

Do  not  disconnect  and  reconnect  the  appliance  to  the  power  supply  when  in 

operation.

• 

Do not pull on the power cord to disconnect it from the power supply.

• 

If  the  power  cord  is  damaged,  it  must  be  replaced  by  the  manufacturer,  an 

authorised representative or a repair facility only

.

• 

Do not perform maintenance or servicing operations on the appliance with wet 

hands or if the appliance is wet.

• 

Before connecting the appliance to the power supply, check that the connection 

unit or socket to which the appliance will be connected is in good condition and 

shows no signs of damage or rust.

• 

For  any  component  or  sub-assembly  containing  a  battery:  do  not  recharge  or 

dismantle the battery, or throw it into a fire. Do not expose it to high temperatures 

or direct sunlight.

• 

In stormy weather, disconnect the appliance from the power supply to prevent it 

from suffering lightning damage.

• 

Do not immerse the appliance in water (with the exception of cleaners) or mud.

vicinity of the moving parts when the appliance is in operation. Moving parts can 

cause serious injury or even death.

EN

Содержание Z550iQ

Страница 1: ...H0673700_REVA 2020 10 More documents on www zodiac com Z550iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...tandards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of...

Страница 3: ...carrying out any operations check that The required input voltage indicated on the appliance information plate corresponds to the mains voltage The mains supply is compatible with the appliance s ele...

Страница 4: ...essures with the consequent risk of severe burns TROUBLESHOOTING All brazing must be carried out by qualified brazers Replacement pipes must always be made of copper in compliance with standard NF EN...

Страница 5: ...3 1 I Winterising 17 3 2 I Maintenance 17 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wiring diagrams 21 Ch...

Страница 6: ...owing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away on brackets Within range of water or mud jets sprays or run off take the effect of the wind into account Ne...

Страница 7: ...djustment valve optional water outlet adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensates fit a 18 pipe on the grooved el...

Страница 8: ...ntry where it is installed The appliance is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker C or D curve for rating see 5 2...

Страница 9: ...nd to pass the cables into the appliance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 4 1 H...

Страница 10: ...on off switch not supplied separate connection cable not supplied When the contact 3 4 is open The device cannot be started in any way The OFF message see image alternates with the current display th...

Страница 11: ...T or ECOSILENCE mode Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more e...

Страница 12: ...blue Cooling mode 1 100 The heat pump is cooling the water 1 50 Heat pump on standby for one of the following reasons inherent to the machine s regulation in normal operation Compressor timer anti sh...

Страница 13: ...valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect th...

Страница 14: ...e previous screen Press several times to return to the main screen where the measured water temperature is displayed 2 4 2 Adjusting the temperature setpoint From the main screen where the measured wa...

Страница 15: ...turning to the setpoint temperature 0 5 C 28 C 27 5 C 28 5 C 30 C Heating green LED Heating green LED Cooling blue LED Temperature setpoint Triggering cancellation threshold for the heating function T...

Страница 16: ...speed HIGH 100 or or or MID 75 LOW 50 The LED strip goes up to HIGH The LED strip fluctuates between LOW MID and HIGH The LED strip fluctuates between LOW and MID Status Heating Objective Quickly incr...

Страница 17: ...ump the Wi Fi signal must be detectable at the place where the appliance is used If this is not the case a technical solution must be provided to amplify the existing signal Rest close to the applianc...

Страница 18: ...tivating the modem s Wi Fi connection is recommended to avoid any risk of the appliance being remotely controlled Do not disconnect the electricity supply when the appliance is running If the electric...

Страница 19: ...onverted to gas If the appliance is not in its defrost cycle this is not normal Switch off and disconnect the appliance immediately and contact your retailer The appliance is not working If there is n...

Страница 20: ...offline J16 connector Reconnect or change the sensor Press E09 ST3 sensor fault defrost sensor Sensor is faulty or offline J14 connector Reconnect or change the sensor Press E10 ST2 sensor fault air i...

Страница 21: ...m E19 Driver compressor communication fault Bad connection between the A1 and A2 boards Check that the CONIN A1 board and AB A2 driver board connectors are correctly connected LED steady red automatic...

Страница 22: ...21 4 4 I Wiring diagrams 4 4 1 Z550iQ MD4 MD5 MD8...

Страница 23: ...22 4 4 2 Z550iQ TD5 TD8 EN...

Страница 24: ...AN HEATER Conveyor resistor GRN YEL Green Yellow HEATER Anti freeze resistor condenser HP High pressure switch J1 Flow switch LED LED electronic board LP Low pressure switch M1 Fan motor M2 Compressor...

Страница 25: ...on A Z550iQ B 50 connector to be glued x2 C Condensate drainage kit 18 D Winterising cap x2 E Winterising cover Heating priority F Technical room kit G Condensation tray H PAC NET cleaning product Inc...

Страница 26: ...l electric current requirement A 9 6 5 12 4 9 5 9 1 6 17 6 7 5 6 3 5 Maximum electric current requirement A 12 5 13 8 6 20 8 Minimum cable section mm 3x2 5 5x2 5 3x6 5x2 5 3G2 5 5G2 5 3G6 5G2 5 Hydrau...

Страница 27: ...26 5 3 I Dimensions and marking Top Bottom Front Rear Grid LED strip User interface Technical access door Pool water inlet Pool water outlet Evaporator Condensates drain EN...

Страница 28: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...

Отзывы: