background image

1

GENERAL WARNINGS

• 

Failure to respect the warnings may cause serious damage to the pool equipment 

or cause serious injury, even death.

• 

Only  a  person  qualified  in  the  technical  fields  concerned  (electricity, 

hydraulics or refrigeration) is authorised to carry out maintenance or 

repair work on the appliance. The qualified technician working on the 

appliance must use/wear personal protective equipment (such as safety 

goggles and protective gloves, etc.) in order to reduce the risk of injury 

occurring when working on the appliance.

• 

Before handling the appliance, check that it is switched off and isolated.

• 

The appliance is intended to be used for pools and spas for a specific purpose; it 

must not be used for any purpose other than that for which it was designed.

• 

This  appliance  is  not  intended  for  use  by  individuals  (including  children)  with 

impaired physical, sensorial or mental abilities, or persons lacking in knowledge 

and experience, unless they receive supervision or prior instructions on using the 

appliance from a person responsible for their safety.

• 

Children must be supervised to ensure that they do not play with the appliance.

• 

This appliance can be used by children over 8 and adults with impaired physical, 

sensory or mental capabilities, or who lack experience and knowledge, if they are 

correctly supervised or have been instructed in how to use the appliance safely and 

understand the hazards involved.

• 

This appliance should not be cleaned or maintained by children without supervision. 

• 

The appliance must be installed according to the manufacturer’s instructions and 

in compliance with local and national standards.

• 

The  installer  is  responsible  for  installing  the  appliance  and  for  compliance  with 

national installation regulations. Under no circumstances may the manufacturer 

be held liable in the event of failure to comply with applicable local installation 

standards.

• 

For any work other than the simple user maintenance described in this manual, the 

product should be referred to a qualified professional.

• 

If the appliance suffers a malfunction, do not try to repair it yourself; instead contact 

a qualified technician.

• 

Refer to the warranty conditions for details of the permitted water balance values 

for operating the appliance.

• 

Deactivating, eliminating or by-passing any of the safety mechanisms integrated 

into the appliance shall automatically void the warranty, in addition to the use of 

spare parts manufactured by unauthorised third-party manufacturers.

• 

Do not spray insecticide or any other chemical (inflammable or non-inflammable) 

in the direction of the appliance, as this may damage the body and cause a fire.

• 

Do not touch the fan or moving parts and do not place objects or your fingers in the 

 WARNINGS

Carefully read the instructions in this manual before using the unit.

• 

Before handling the appliance, it is vital that you read this installation and user 

manual, as well as the "Warranties" booklet delivered with the appliance. Failure 

to do so may result in material damage or serious or fatal injury and will void the 

warranty.

• 

Keep and pass on these documents for later viewing throughout the appliance's 

service life.

• 

The distribution or modification of this document in any way is prohibited, without 

prior authorisation from the manufacturer.

• 

The manufacturer is constantly developing its products to improve their quality. 

The information contained herein may therefore be modified without notice. 

Содержание Z550iQ

Страница 1: ...H0673700_REVA 2020 10 More documents on www zodiac com Z550iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...tandards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of...

Страница 3: ...carrying out any operations check that The required input voltage indicated on the appliance information plate corresponds to the mains voltage The mains supply is compatible with the appliance s ele...

Страница 4: ...essures with the consequent risk of severe burns TROUBLESHOOTING All brazing must be carried out by qualified brazers Replacement pipes must always be made of copper in compliance with standard NF EN...

Страница 5: ...3 1 I Winterising 17 3 2 I Maintenance 17 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wiring diagrams 21 Ch...

Страница 6: ...owing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away on brackets Within range of water or mud jets sprays or run off take the effect of the wind into account Ne...

Страница 7: ...djustment valve optional water outlet adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensates fit a 18 pipe on the grooved el...

Страница 8: ...ntry where it is installed The appliance is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker C or D curve for rating see 5 2...

Страница 9: ...nd to pass the cables into the appliance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 4 1 H...

Страница 10: ...on off switch not supplied separate connection cable not supplied When the contact 3 4 is open The device cannot be started in any way The OFF message see image alternates with the current display th...

Страница 11: ...T or ECOSILENCE mode Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more e...

Страница 12: ...blue Cooling mode 1 100 The heat pump is cooling the water 1 50 Heat pump on standby for one of the following reasons inherent to the machine s regulation in normal operation Compressor timer anti sh...

Страница 13: ...valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect th...

Страница 14: ...e previous screen Press several times to return to the main screen where the measured water temperature is displayed 2 4 2 Adjusting the temperature setpoint From the main screen where the measured wa...

Страница 15: ...turning to the setpoint temperature 0 5 C 28 C 27 5 C 28 5 C 30 C Heating green LED Heating green LED Cooling blue LED Temperature setpoint Triggering cancellation threshold for the heating function T...

Страница 16: ...speed HIGH 100 or or or MID 75 LOW 50 The LED strip goes up to HIGH The LED strip fluctuates between LOW MID and HIGH The LED strip fluctuates between LOW and MID Status Heating Objective Quickly incr...

Страница 17: ...ump the Wi Fi signal must be detectable at the place where the appliance is used If this is not the case a technical solution must be provided to amplify the existing signal Rest close to the applianc...

Страница 18: ...tivating the modem s Wi Fi connection is recommended to avoid any risk of the appliance being remotely controlled Do not disconnect the electricity supply when the appliance is running If the electric...

Страница 19: ...onverted to gas If the appliance is not in its defrost cycle this is not normal Switch off and disconnect the appliance immediately and contact your retailer The appliance is not working If there is n...

Страница 20: ...offline J16 connector Reconnect or change the sensor Press E09 ST3 sensor fault defrost sensor Sensor is faulty or offline J14 connector Reconnect or change the sensor Press E10 ST2 sensor fault air i...

Страница 21: ...m E19 Driver compressor communication fault Bad connection between the A1 and A2 boards Check that the CONIN A1 board and AB A2 driver board connectors are correctly connected LED steady red automatic...

Страница 22: ...21 4 4 I Wiring diagrams 4 4 1 Z550iQ MD4 MD5 MD8...

Страница 23: ...22 4 4 2 Z550iQ TD5 TD8 EN...

Страница 24: ...AN HEATER Conveyor resistor GRN YEL Green Yellow HEATER Anti freeze resistor condenser HP High pressure switch J1 Flow switch LED LED electronic board LP Low pressure switch M1 Fan motor M2 Compressor...

Страница 25: ...on A Z550iQ B 50 connector to be glued x2 C Condensate drainage kit 18 D Winterising cap x2 E Winterising cover Heating priority F Technical room kit G Condensation tray H PAC NET cleaning product Inc...

Страница 26: ...l electric current requirement A 9 6 5 12 4 9 5 9 1 6 17 6 7 5 6 3 5 Maximum electric current requirement A 12 5 13 8 6 20 8 Minimum cable section mm 3x2 5 5x2 5 3x6 5x2 5 3G2 5 5G2 5 3G6 5G2 5 Hydrau...

Страница 27: ...26 5 3 I Dimensions and marking Top Bottom Front Rear Grid LED strip User interface Technical access door Pool water inlet Pool water outlet Evaporator Condensates drain EN...

Страница 28: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...

Отзывы: