background image

3

Recycling

This symbol is required by the European directive DEEE 2012/19/EU (directive on waste electrical and electronic 

equipment) and means that your appliance must not be thrown into a normal bin. It will be selectively collected 

for the purpose of reuse, recycling or creating value. If it contains any substances that may be harmful to the 

environment, these will be eliminated or neutralised. Contact your retailer for recycling information.

• 

During the appliance's annual sealing test in accordance with applicable legislation, 

the  high  and  low  pressure  switches  must  be  checked  to  ensure  that  they  are 

securely fastened to the cooling circuit and that they cut off the electrical circuit 

when tripped.

• 

During maintenance work, ensure there are no traces of corrosion or oil around 

the cooling components.

• 

Before beginning work on the cooling circuit, stop the appliance and wait for a few 

minutes before fitting the temperature and pressure sensors. Some elements such 

as the compressor and piping may reach temperatures in excess of 100°C and high 

pressures with the consequent risk of severe burns.

TROUBLESHOOTING

• 

All brazing must be carried out by qualified brazers.

• 

Replacement pipes must always be made of copper in compliance with standard 

NF EN 12735-1.

• 

Leak detection; pressure test:

 -

never use oxygen or dry air (risk of fire or explosion)

 -

use  dry  nitrogen  or  the  mixture  of  nitrogen  and  refrigerant  indicated  on  the 

information plate,

 -

the test pressure for both the high and low pressure circuits must not exceed 

42 bar (for R410A) in cases where the appliance is equipped with the optional 

pressure gauge.

• 

The high pressure circuit pipes are made of copper and have a diameter equal to or 

greater than 1’’5/8. A certificate as indicated in §2.1 in compliance with standard 

NF EN 10204 must be requested from the supplier and filed in the installation's 

technical file.

• 

Technical data relative to the safety requirements of the various applicable directives 

are indicated on the information plate. All this information must be recorded in the 

appliance's  installation  manual,  which  must be kept in  its technical file: model, 

code,  serial  number,  maximum  and  minimum  OT,  OP,  year  of  manufacture,  CE 

marking,  manufacturer’s  address,  coolant  and  weight,  electrical  parameters, 

thermo-dynamic and acoustic performance.

Содержание Z550iQ

Страница 1: ...H0673700_REVA 2020 10 More documents on www zodiac com Z550iQ Instructions for installation and use English Heat pump Translation of the original instructions in French EN...

Страница 2: ...tandards The installer is responsible for installing the appliance and for compliance with national installation regulations Under no circumstances may the manufacturer be held liable in the event of...

Страница 3: ...carrying out any operations check that The required input voltage indicated on the appliance information plate corresponds to the mains voltage The mains supply is compatible with the appliance s ele...

Страница 4: ...essures with the consequent risk of severe burns TROUBLESHOOTING All brazing must be carried out by qualified brazers Replacement pipes must always be made of copper in compliance with standard NF EN...

Страница 5: ...3 1 I Winterising 17 3 2 I Maintenance 17 Troubleshooting 18 4 1 I Appliance behaviour 18 4 2 I Error code display 19 4 3 I Lighting of LEDs on the printed circuit board 20 4 4 I Wiring diagrams 21 Ch...

Страница 6: ...owing towards a permanent or temporary obstacle awning brushwood etc less than 5 metres away on brackets Within range of water or mud jets sprays or run off take the effect of the wind into account Ne...

Страница 7: ...djustment valve optional water outlet adjustment valve optional water treatment minimum distance Connection to a standard filtration circuit To evacuate the condensates fit a 18 pipe on the grooved el...

Страница 8: ...ntry where it is installed The appliance is provided for connection to a general power supply with a TT and TN S neutral regime Electrical protection by circuit breaker C or D curve for rating see 5 2...

Страница 9: ...nd to pass the cables into the appliance The cables used for the options and the power cord must be kept separate risk of interference using a collar inside the appliance just after the glands 1 4 1 H...

Страница 10: ...on off switch not supplied separate connection cable not supplied When the contact 3 4 is open The device cannot be started in any way The OFF message see image alternates with the current display th...

Страница 11: ...T or ECOSILENCE mode Cover the pool with a sheet bubble canopy canvas etc to prevent heat loss Take advantage of a period with mild outdoor temperatures on average 10 C at night it will be even more e...

Страница 12: ...blue Cooling mode 1 100 The heat pump is cooling the water 1 50 Heat pump on standby for one of the following reasons inherent to the machine s regulation in normal operation Compressor timer anti sh...

Страница 13: ...valve E by half the air which has built up in the heat pump condenser and the filtration circuit will bleed out If valves D and E are not present open valve A wide and close valve C by half Connect th...

Страница 14: ...e previous screen Press several times to return to the main screen where the measured water temperature is displayed 2 4 2 Adjusting the temperature setpoint From the main screen where the measured wa...

Страница 15: ...turning to the setpoint temperature 0 5 C 28 C 27 5 C 28 5 C 30 C Heating green LED Heating green LED Cooling blue LED Temperature setpoint Triggering cancellation threshold for the heating function T...

Страница 16: ...speed HIGH 100 or or or MID 75 LOW 50 The LED strip goes up to HIGH The LED strip fluctuates between LOW MID and HIGH The LED strip fluctuates between LOW and MID Status Heating Objective Quickly incr...

Страница 17: ...ump the Wi Fi signal must be detectable at the place where the appliance is used If this is not the case a technical solution must be provided to amplify the existing signal Rest close to the applianc...

Страница 18: ...tivating the modem s Wi Fi connection is recommended to avoid any risk of the appliance being remotely controlled Do not disconnect the electricity supply when the appliance is running If the electric...

Страница 19: ...onverted to gas If the appliance is not in its defrost cycle this is not normal Switch off and disconnect the appliance immediately and contact your retailer The appliance is not working If there is n...

Страница 20: ...offline J16 connector Reconnect or change the sensor Press E09 ST3 sensor fault defrost sensor Sensor is faulty or offline J14 connector Reconnect or change the sensor Press E10 ST2 sensor fault air i...

Страница 21: ...m E19 Driver compressor communication fault Bad connection between the A1 and A2 boards Check that the CONIN A1 board and AB A2 driver board connectors are correctly connected LED steady red automatic...

Страница 22: ...21 4 4 I Wiring diagrams 4 4 1 Z550iQ MD4 MD5 MD8...

Страница 23: ...22 4 4 2 Z550iQ TD5 TD8 EN...

Страница 24: ...AN HEATER Conveyor resistor GRN YEL Green Yellow HEATER Anti freeze resistor condenser HP High pressure switch J1 Flow switch LED LED electronic board LP Low pressure switch M1 Fan motor M2 Compressor...

Страница 25: ...on A Z550iQ B 50 connector to be glued x2 C Condensate drainage kit 18 D Winterising cap x2 E Winterising cover Heating priority F Technical room kit G Condensation tray H PAC NET cleaning product Inc...

Страница 26: ...l electric current requirement A 9 6 5 12 4 9 5 9 1 6 17 6 7 5 6 3 5 Maximum electric current requirement A 12 5 13 8 6 20 8 Minimum cable section mm 3x2 5 5x2 5 3x6 5x2 5 3G2 5 5G2 5 3G6 5G2 5 Hydrau...

Страница 27: ...26 5 3 I Dimensions and marking Top Bottom Front Rear Grid LED strip User interface Technical access door Pool water inlet Pool water outlet Evaporator Condensates drain EN...

Страница 28: ...rty of their respective owners ZPCE ZA La Balme 31450 Belberaud S A S U au capital de 1 267 140 SIRET 395 068 679 00046 RCS TOULOUSE Votre revendeur Your retailer Mod le appareil Appliance model Num r...