Information about the thermal capacity of the pellet burner of series “GP” at
different values of the thermal capacity parameter P2 is shown in the following
table.
Thermal capacity of the pellet burner , [kW]
Type
GP 25
GP 32
P2
[number of LED blinking]
- -
0 5.0
5.0
1 6.0
6.0
2 8.0
8.0
3 11.0
11.0
4 14.0
14.0
5 18.0
18.0
6 21.0
21.0
7 25.0
25.0
8 -
28.0
9 -
32.0
Table 5.3.
Thermal capacity of a system: pellet burner of series “GP” – heat
consumer unit, according to the value of thermal capacity parameter P2 (and the
burner’s type);
ATTENTION
:
In case of change of the fuel type (for example changing the
pellets category) an appropriate adjustment of the operating parameters
requirement could arise in order to achieve thermal capacity and high efficiency
of the system (i.e. the thermal capacity by the potentiometer and the air flow rate
by the flap).
5.3.1.
Decreasing thermal capacity of the burner
Thermal capacity of the burner is decreased by turning the position of the
potentiometer, positioned on the interface panel of the burner, in direction
to lower set-point – turn the potentiometer in direction anticlockwise,
which will result in decreased fuel consumption rate;
5.3.2.
Increasing thermal capacity of the burner
Thermal capacity of the burner is increased by turning the position of the
potentiometer, positioned on the interface panel of the burner, in direction
to upper set-point – turn the potentiometer in direction clockwise, which
will result in increased fuel consumption rate;