p.
27/61
5.2.2.
Color scale for synchronization of the air flow rate with the
thermal capacity of the burner
Figure 5.2
. Color scale for synchronization of the air flow rate according to the
thermal capacity of the pellet burner of series “GP cs”.
The color scale is positioned on the cover of the pellet burner. Use this color
scale in order to set the position of the air control flap, driven by the lever, in
order to adjust the air flow rate. The lever passes though a small opening of the
burner’s cover. The position of the lever should correspond to the position of the
thermal capacity control potentiometer, in order to sustain the high combustion
efficiency and reliability if the pellet burner of series “GP cs”.
5.2.3.
Automatic pellet burner power supply
ATTENTION :
all installation and servicing procedure, which are made on
the electrical system of the pellet burner, by removing the cover and/or other
protecting elements, should be performed by authorized technician only.
The burner should be connected to the power supply of the unit, at which
it is attached and the appropriate safety rules should be satisfied. Use the
attached to the main unit power supply cable and connect it to the control
and power supply box of the heat consumer. If the heat consumer is a hot
Lever to adjust the
position of the air control
flap
Color scale, which is used
to adjust the position of
the air control flap