802411 v3.05 09.20 HT BC Compact Instructions
Page 17 of 28
John Guest
fittings
(Insertion and removal)
Be careful when cutting the poly tube so that there are no rough edges and that the tube is not distorted.
1. Use a sharp knife to ensure the tube has a clean,
straight edge. Do not cut at an angle.
2. Remove any swarf or unwanted material.
3. Push the tube into the John Guest fitting making sure
all connections to the John Guest fittings are pushed
in past the “O”ring to full depth, at least 15-16mm.
4. Check for a good joint by pulling back on the tube. If
the tube comes out, of the fitting, repeat the above
step.
5. To remove the tube, press the collet into the fitting
and at the same time pull back on the tube.
If no external filter is in
-
stalled, select position A.
If an external filter is
installed, select position B
NOTE:
Before you install a unit, determine whether a water softener or an external filter is required.
4.1
External Bypass Valve
The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter
and only be filtered by external filtration. The diverter valve is located at the rear panel of the Zip HydroTap
Command Centre on the filter door side. Refer to the image below to determine the correct valve position.
Section 4
Command Centre Installation
A
Rotate 90°
only
1
2
3
4
B
Rotate 90°
only
1
2
3
4
4.2
Hose and tube fitting
•
Remove all caps from the top of the Command
Centre (except the mixer caps)
•
Only remove the mixer caps if a mixer tap is to be
fitted.
•
Fit the foam insulation to the Blue and to the
White tubes after trimming them to length
•
Install the mains water braided hoses to the
Command Centre before locating the unit in
place.
NOTE: Do not overtighten
Con Strainer
90° Bend end
of Braided Hose
To HydroTap
Command Centre
Braided hose for
Mains Water Supply
From Mains
Water Supply