Thank you for purchasing a Zip HydroTap. Please read and follow these instructions carefully to ensure safe 

and trouble free service. If service is required, please call 1800 460 222.

What is the Zip HydroTap ?

The Zip HydroTaps are electronically controlled, filtered, Boiling water and Chilled water drinking systems for 

kitchens and tea rooms. The HydroTap units are under bench drinking water appliances with a dispensing 

tap mounted on a sink or bench, which has been designed for commercial applications.  These units utilise 

a conventional refrigerant compressor to chill the water and an immersion heating element to boil the water. 

These units dispense boiling water (factory set to 98°C) and chilled water (factory set to 6-10°C). These units 

are NOT designed to be used for sanitary fixtures.

The Boiling water units are fitted with a tap mounted, child safety lock. In addition, there are various energy 

saving options accessible via the main menu. Each unit is equipped with a self-calibrating program which 

caters for altitude adjustment. The water filter is a disposable item which will require periodic replacement and 

is covered by a limited OEM warranty.

It is important that the Installation be done safely, correctly and completely, in order to utilise all the benefits 

the HydroTap can provide. Each unit can be ordered with the Tap Head Assembly for Disabled use. The 

disabled levers are supplied with Braille caps for the visually impaired. 

General Product Features

ON-OFF Switch

Command centre

Din plug        

   

(for accessories)

IEC Socket

Содержание HydroTap G4 BC100/75

Страница 1: ...802411 v3 05 09 20 HT BC Compact Instructions Page 1 of 28 Affix Model Number Label Here 802411 BC100 75 range Zip HydroTap G4 Installation and Operating Instructions ...

Страница 2: ...assic All In One Celsius All In One Arc Cube Tap Classic Tap Elite Tap These taps are directly compatible with the HydroTap G4 Command Centre The All In One Tap is a stand alone tap that may be used as an alternative to any of the above combinations The Mixer tap range is an additional series of taps that may be used in conjunction with any one of the taps shown above to create 4 in 1 models ...

Страница 3: ...l Models 11 2 2 Cupboard Air Circulation 12 STEP 3 Install the Booster Heater if required Section 3 Booster Heater Installation 3 1 Product Description 14 3 2 Installation Procedure 15 3 3 To Remove Install the appliance 15 3 4 Braided Hose Connections 16 STEP 4 Install the Command Centre Section 4 Command Centre Installation 4 1 External Bypass Valve 17 4 2 Hose and tube fitting 17 4 3 Model BC 1...

Страница 4: ...ppliance F Check the under counter cupboard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have been tightened 3 Ensure the outlet and vent pipes are positioned to drain correctly 4 Ensure there is adequate ventilation 5 Check all tubes from the Command Ce...

Страница 5: ...se units dispense boiling water factory set to 98 C and chilled water factory set to 6 10 C These units are NOT designed to be used for sanitary fixtures The Boiling water units are fitted with a tap mounted child safety lock In addition there are various energy saving options accessible via the main menu Each unit is equipped with a self calibrating program which caters for altitude adjustment Th...

Страница 6: ... Installation procedures must be carried out by a suitably qualified tradesperson The power cable and power outlet must be in a safe visible position for connection Venting Sometimes steam and or condensed droplets may discharge through a vent outlet at the tap If the tap is not installed using the Font pedestal ensure the tap body is located so the tap outlet safely dispenses into the sink bowl a...

Страница 7: ... 3500 Electrical Wiring Rules AS NZS 3000 4 This HydroTap product is rated for 230V 50Hz AC operation 5 This unit must be installed with adequate clearances of 50mm on all sides and 200mm above to allow for air circulation Additional means of ventilation is critical if the vent kit as supplied cannot be fitted 6 Flush water supply lines before any plumbing connections are made to prevent sediment ...

Страница 8: ...t 1 x Inlet vent 1 x Outlet vent 9 x Screws 1 off HydroTap Booster Heater hoses supplied with BCHAV model 1 x Flow Restrictor and Tee piece for Mixer taps and select models 1 x Mixer Tap for 4 In 1 and select models with hoses 1 x Installation Instructions this book and 1 x User Guide Accessories Description HydroTap Booster Water System with connection hoses Font Kit for Arc Cube Models Font Kit ...

Страница 9: ...80 x 470 x 335 24 All in One BCHA A 100 75 1x10A 2 05 N A 280 x 470 x 335 24 BCHA AV140 75 2x10A 2 05 2 2 280 x 470 x 335 24 Note The Cup measurement 167ml and the Glass measurement 200ml Chilled water will continue to be dispensed after the rated capacity has been used although this may be at slightly higher temperature Models BC Boiling and Chilled BCHA 4 in 1 A All in One Mains AV All in One Ve...

Страница 10: ...tion point and the stop cock will not be obstructed when the Command Centres are installed For the mains pressure All In One an external hot and cold water supply will be required If an external filtration or water softening device is required then it is important to allow extra space for these items A cold water supply with a minimum working pressure of 172kPa and a maximum working pressure of 70...

Страница 11: ...ly only if the recommend ed air gaps are achieved during installation It is important that the 4mm door buffers are fitted to the inside edge of the cupboard door to allow sufficient air circulation inside the cupboard see diagram below IMPORTANT Allow clearance of 50mm either side and 200mm above the Command Centre Section 2 Ventilation Section 1 Tap Installation Refer to the Tap installation ins...

Страница 12: ...ations where the cupboard space temperature is near 35 C or higher the inlet vent See Item B below and silicon buffers need to be fitted If the airflow is still insufficient to maintain normal operating temperatures then the door outlet vent See item D below will need to be fitted Alternatively a fan kit may be installed using the AUX din plug of the right hand side of the appliance Contact your l...

Страница 13: ... vent 1 Mark out and cut the air inlet and door outlet holes as shown 2 Ensure the air inlet vent and air outlet vent are positioned at opposite ends of the same cupboard space 3 Fit the inlet vent as shown and secure with 5 screws 4 Fit the outlet vent as shown in the hottest part top of the cupboard and secure with 4 screws B D ...

Страница 14: ...40 cups 280mm Note Note 1 water connection Blue marking water in Red marking water out The braided hoses cannot be lengthened Note Note 2 The electrical cable length is 1 0 metre Note Note 3 Position the Booster within reach of the fixed hose lengths keeping the Booster as close as possible to the Com mand Centre inlet outlet fittings Note Note 4 Ensure the Booster heater is mounted in an upright ...

Страница 15: ...ons on top of the Booster The hot water outlet hose must be thermally insulated with the insulation provided Tilt Forward Lift UP Release NOTE Remove the backing plate for wall mounting 3 3 To Remove Install the appliance 1 Insert a flat head screwdriver all the way into the lock 2 Gently angle the screwdriver upwards by approximately 10 as shown in the image below 3 Pull the appliance forwards by...

Страница 16: ...Bypass Out fitting to the water inlet of the booster unit Marked Blue and from the outlet of the booster unit Marked Red to the Bypass IN fitting on the Zip HydroTap unit Avoid exerting any mechanical pressure on the appliance This can be achieved by applying a spanner on the flats of the inlet and outlet connections when tightening the braided hose connectors Do not overtighten Tighten the braide...

Страница 17: ... you install a unit determine whether a water softener or an external filter is required 4 1 External Bypass Valve The diverter bypass valve allows the user to choose to have the boiling feed water bypass the internal filter and only be filtered by external filtration The diverter valve is located at the rear panel of the Zip HydroTap Command Centre on the filter door side Refer to the image below...

Страница 18: ... Min 70mm USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gradient to the Hydrotap to al...

Страница 19: ...Mains Pressure RED CLEAR BLUE BRAIDED USB MAINS IN MIXER OUT MIXER IN BOILING OUT BYPASS IN VENT BYPASS OUT CHILLED OUT Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gr...

Страница 20: ...onnections BRAIDED BRAIDED BRAIDED BRAIDED Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gradient to the Hydrotap to allow all Hydrotap to allow all water to drain back...

Страница 21: ...Mains hose length is 750mm Plug and Cord length is 1800mm Position the Command Centre close to the outlet tap within reach of the hose and cord lengths supplied Note Note the hoses the hoses need to have a need to have a constant downward constant downward gradient to the gradient to the Hydrotap to allow all Hydrotap to allow all water to drain back water to drain back into the tanks into the tan...

Страница 22: ...d allow at least 10 litres of water to flush through the filter 4 The product details will be displayed in the screen 5 Once the filter flush is finished turn the stop cock OFF then press Stop to end filter flush mode 6 Press Next for the Boiling Calibration screen A new filter cartridge is provided but NOT fitted inside the filter door Unpack the new filter cartridge and write today s date on the...

Страница 23: ...correct selection for the Booster will affect product performance NOTE Depending on your location you may need to re set the internal clock See section G of the user guide to check and if necessary reset the Date and Time for your time zone 1 Press the MENU button for main menu 2 Press the Install button 3 Press the Booster button 4 In the next screen press YES to enable the Booster 5 Turn the Boo...

Страница 24: ... time of the installation All direct natural sun light must be shaded from the HydroTap during the calibration This can be achieved by closing any nearby curtains blinds or by shielding the HydroTap with a dark cloth 5 5 Safety Sensor Calibration 5 6 Command Centre Flush All G4 HydroTap products are currently sanitised after functional test at the factory Due to the sanitisation process residue fr...

Страница 25: ...lation Call Zip Service Condenser sensor Open Internal fault Check ventilation Call Zip service Heater fuse driver fault Internal fault Call Zip Service Heater driver fault No hot water Call Zip Service Compressor driver fault No chilled water Call Zip Service Hot sensor degraded Internal fault Call Zip Service Condenser overtemp Blocked air filter Remove blockage Clean filter check user guide A D...

Страница 26: ... v3 05 09 20 HT BC Compact Instructions End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection centre details ...

Страница 27: ...802411 v3 05 09 20 HT BC Compact Instructions Page 27 of 28 Notes ...

Страница 28: ...800 ZIP TAP 1800 947 827 The terms Zip and HydroTap are registered trade marks of Zip Water Aust Pty Ltd Zip products described in this publication are manufactured under one or more patents and further patent applications are pending As Zip policy is one of continuous product improvement changes to specifications may be made without prior notice Images in this booklet have been modified and may n...

Отзывы: