19
11.5 Setting the end position damping for the SBZ series
CAUTION
Risk of injury due to uncontrolled movements
Risk of injury in the event of uncontrolled movement of the product when the power supply is connected.
►
Switch off the power supply to the machine before carrying out any work.
►
Secure the power supply against being switched on unintentionally.
►
Check the machine for any residual energy that may be present.
NOTICE
Shock absorbers may not be used as an end stop.
►
Make sure that the stop screws come into contact with the respective stop surfaces.
►
Reset the shock absorber when you change the swivel angle.
NOTICE
The damping behavior changes as the oil in the shock absorber heats up.
►
Enter the operating temperature settings for the shock absorbers.
• After approximately 30 cycles in the cycle time that is selected later, the shock absorber reaches operating
temperature.
• If a break time of > 1 minute is exceeded, no shock absorber warm-up is required.
INSTALLATION AND OPERATING INSTRUCTIONS:
SB/SBZ
DDOC00246 / d
EN / 2022-11-09
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com