20
►
Switch off the power supply.
cs
7
cr
2
►
Loosen the lock nut.
►
Rotate the shock absorber clockwise until
the output shaft moves.
►
During this process, make sure that
the piston rod in the shock absorber is
pushed in completely.
►
Rotate the shock absorber counter-
clockwise one turn.
Ö
This achieves maximum damping.
►
Loosely attach the lock nut.
►
Remove persons and objects from the
swivel range.
►
Switch on the power supply.
►
Slightly open the adjustment screws of the
flow control valves.
►
Apply compressed air to the product on
alternating sides.
►
Check to ensure that there is uniform swivel
movement and exhaust air flow-controlled
movement to the end positions.
►
If necessary, readjust the adjustment
screws and shock absorbers.
►
Tighten the lock nut.
2
Flow control valve
7
Shock absorber
cr
Lock nut
cs
Adjustment screw
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
SB/SBZ
DDOC00246 / d
EN / 2022-11-09