37
Zimmer GmbH
•
Im Salmenkopf 5
•
77866 Rheinau, Germany
•
+49 7844 9138 0
•
+49 7844 9138 80
•
www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
2-jaw parallel gripper, electric, GEP2000IL-03 series
EN / 2021-06-25
DDOC01219 / a
Index
Name
Data format Access right
Values
Description
0x114
(276)
Subindex
1 to 4
WorkPosition/
BasePosition
tolerance window
UINT16
Read/write
0 to 65535
Setting the BasePosition and
WorkPosition tolerance window
• Subindex 0: Read/write all
• Subindex 1: from BasePosition
to the outside
• Subindex 2: from BasePosition
to the inside
• Subindex 3: from WorkPosition
to the inside
• Subindex 4: from WorkPosition
to the outside
0x22f
(559)
Holding current
UINT16
Read/write
0 to 1100
Amperage for the subsequent
current feed after gripping process
has been completed.
0x230
(560)
Holding time
UINT16
Read/write
0 to 1000
Time period for subsequent
current feed after gripping process
has been completed [in ms].
0x232
[562]
Emergency Mode UINT16
Read/write
0 to 1
Deactivating the message 0x400 is
done by the following ISDU:
• Index = 562 (decimal)
• Subindex = 0
•
Value = 0
Activating the message 0x400 is
done by the following ISDU:
• Index = 562 (decimal)
• Subindex = 0
•
Value = 1