8.3 Parameters
8.3.1 "ControlWord" parameter
NOTICE
In the "ControlWord" parameter, only one single bit or the value 0 may be set at a time. Only the values listed in
the following table are valid.
Parameters
Decimal value
Hexadecimal value
Data transfer
1
0x1
WritePDU
2
0x2
ResetDirectionFlag
4
0x4
Teach
8
0x8
MoveToBase
256
0x100
MoveToWork
512
0x200
JogToWork "+"
1024
0x400
JogToBase "-"
2048
0x800
ErrorReset
32768
0x8000
Name
"ControlWord"
Data format
UINT16
Permission
Write
Transfer
Cyclical
Value range
0 to 65535
"ControlWord" structure:
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Byte 1
"ErrorReset"
-
-
-
"JogToBase"
"JogToWork"
"MoveToWork" "MoveToBase"
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Byte 2
-
-
-
-
"Teach"
"ResetDirec-
tionFlag"
"WritePDU"
"DataTransfer"