DDOC01219 / a
12 Table with acyclic data (ISDU)
INFORMATION
IO-Link distinguishes between cyclic process data (PDU) and acyclic data (ISDU).
Currently, access to acyclic data is not arranged very conveniently for all control system and IO-Link master
combinations. For this reason, the GEP2000IL series can be used completely without the need for acyclic data.
This makes it as easy as possible for the customer to control the product.
Zimmer Customer Service is available to provide you with assistance if you have any questions.
Index
Name
Data format Access right
Values
Description
0x40
(64)
Status
UINT16
Read
0 to 65535
Reflection of the process data
0x41
(65)
Diagnosis
UINT16
Read
0 to 65535
Reflection of the process data
0x42
(66)
Cycle counter
UINT32
Read
0 to 4294967295 Current
numbers of cycles
0x43
(67)
Temperature
UINT16
Read
0 to 100 °C
Current
temperature
0x44
(68)
ControlWord
UINT16
Read
0 to 65535
Reflection of the process data
0x45
(69)
Error code
STRING
Read
1 to 32
Current
error code
0x46
(70)
Error counter
UINT32
Read
0 to 4294967295 Current
error counter
0x100
(256)
Actual position
UINT16
Read
0 to max. stroke
of the product
Reflection of the process data
0x101
(257)
TeachPosition
UINT16
Read
0 to max. stroke
of the product
Reflection of the process data
0x102
(258)
WorkpieceNo.
UINT8
Read
0 to 32
Reflection of the process data
0x103
(259)
DeviceMode
UINT8
Read
1 to 95
Reflection of the process data
0x104
(260)
PositionTolerance UINT8
Read
0 to 255
Reflection of the process data
0x105
(261)
GripForce
UINT8
Read
1 to 130%
Reflection of the process data
0x107
(263)
DriveVelocity
UINT8
Read
1 to 100%
Reflection of the process data
0x108
(264)
BasePosition
UINT16
Read
0 to max. stroke
of the product
Reflection of the process data
0x109
(265)
ShiftPosition
UINT16
Read
0 to max. stroke
of the product
Reflection of the process data
0x10A
(266)
WorkPosition
UINT16
Read
0 to max. stroke
of the product
Reflection of the process data