Operating Manual
ZIGOR SOLAR HIT3C
36
© ZIGOR
53
Inverter supply error
Supply error
Serious
Event FpwFail
Auxiliary
supply failure
54
DC polarity inversion
DC Pol. Failure
Serious
Photovoltaic voltage < VpvInv
5% hysteresis
55
System error
System error
Serious
Event ESistema
General
system error
60
VBusMin
Minimum Bus Voltage
Grave
Tensión condesadores > menor
Vcond con histéresis 5%
61
VBusMax
Maximum Bus Voltage
Grave
Tensión condesadores > mayor
Vcond con histéresis 5%
62
Fuse
Fuse
Leve
Fuse Failure
63
Genset
Genset
Leve
Genset Failure
64
Batery
Batery
Leve
Fallo de las Baterías
65
VBat Max
VBatMax
Grave
Battery voltage > Vbat 5%
hysteresis
66
VBat Min
VBatMin
Grave
Battery Voltage < Vbat 5%
hysteresis
67
MET Comm. Error
MET Communication
Failure
Leve
Fallo comunicación MET
68
MET Rad. Alarm
MET Radiation Alarm
Leve
69
MET Loop Alarm
MET Loop Alarm
Leve
70
DC Short Circuit
DC ShortCircuit
Severe
Photovoltaic voltage < VpvCorto
and input current> IEntCorto
with 5% hystereisis
71
Emergency stop
Emergency Stop
Serious
No event Fhab
Emergency
button
72
Open Door
Open Door
Severe
Event Door
Door open
73
General switch off
General Switch
Severe
Event IntGeneral
General
switch open
74
Inverter persistent error
Invert. Failure
Severe
Errors (41,43,45,46 or 47) occur
more than 3 times in the same
day
75
Discharge Error
Inverter Bus Discharge
Error
Serious
If Conv. Status Is
ERROR_DESCARGA
80
STR. Comm. Error 1
Strings Current Measures
Comm. Failure
Minor
Communication failure with
current captation module of the
String box
81
STR. Comm. Error 2
Strings Protections Comm.
Failure
Minor
Communication failure with
protection captation module of
the String box
82
STR. Overload
Strings Overload Circuit
Breaker
Minor
The overload protection of the
String box is open
83
STR. Overvoltage
Strings Overvoltage
Protection
Minor
The overvoltage protection of the
String box is open
84
STRING 1 I LOW
String 1 Current under limit Minor
Current < Offset Param. above
average current
85
STRING 2 I LOW
String 2 Current under limit Minor
Current < Offset Param. above
average current
Содержание SOLAR HIT3C
Страница 2: ......
Страница 38: ...Manual de Operaci n ZIGOR SOLAR HIT3C 34 ZIGOR Fig 6 6 Pantalla Hist rico de Eventos...
Страница 89: ...Operating Manual ZIGOR SOLAR HIT3C ZIGOR 29 Fig 6 4 Registered Power Screen Fig 6 5 Daily Energy Screen...
Страница 94: ...Operating Manual ZIGOR SOLAR HIT3C 34 ZIGOR Fig 6 10 Events History Screen...
Страница 115: ......