STW164IP
12660-0710-00
Page
26 / 30
www.ziehl.de
Error:
bit-0 (valence = 1): Volume flow exceeded
bit-1 (valence = 2): End position error
bit-2 (valence = 4): Error on RS485 BUS (communication to STW161M / STW168M)
bit-3 (valence = 8): Error on supply voltage of STW161M / STW168M (voltage too high / too low)
bit-4 (valence = 16): Error in internal memory
bit-5 (valence = 32): Parameter error
bit-6 (valence = 64): Error in parameter for priority (STW161M/ STW168M - priority the same several times)
bit-7 (valence = 128): internal device error
bit-8 (value = 256):Error on supply voltage of STW164IP (voltage too high / too low)
bit-9 (valence = 512): Error on display of STW164IP
No errors are logged during a simulation on the device / via the website.
A data record is always logged when the device is started (as soon as a current date/time has been obtained
from the time server, but after 20 s at the latest).
11.7 Register - Counter
•
STW164IP: Operating hours counter
•
STW164IP: Switch-on times of relay extraction, cleaning, K3 and K4 (values can be reset)
•
STW161M / STW168M (Address 00...31): Switch-on times of machines (values can be reset)
•
STW161M / STW168M (Address 00....31): Number of slider openings (values can be reset)
The switch-on times are only updated after the individual functions have been switched off again.
12
Firmware Update
If a newer firmware version is available, an update can be carried out as follows...
1. Website "System" - Firmware update STW164IP - Update notification =
active
:
>
An update message appears when the device is accessed via a web browser
>
Confirm message, the current firmware will be downloaded and installed
2. Website "System" - Firmware update STW164IP - Update notification =
inactive
:
>
Press the "Update" button, the current firmware will be downloaded and installed
3. Download the firmware from
and then ...
Website “System” - Firmware update STW164IP - Manual update installation