![ZIEHL-ABEGG FXET4AMQ Скачать руководство пользователя страница 82](http://html1.mh-extra.com/html/ziehl-abegg/fxet4amq/fxet4amq_operating-instructions-manual_3705127082.webp)
13
Function extension and version of software
Software D1628A
, display version
menu group Start under Fcontrol
Version
Date
Function from new version
1.03
17.09.09
Start
: Motor OFF / ON
IO Setup
: E1, E2 Modus
Modbus
: readout serial number via Modbus possible.
1.04
04.11.09
No low voltage message for PFC = OFF
1.06
12.05.10
Motor Setup
new factory settings:
Rampup time = 10 sec
Rampdown time = 10 sec
DC brake mode = 1
DC brake time = 5 sec
DC brake level = 10 %
14
Enclosure
14.1
Technical data
Type
FXET4AMQ
FXET6AMQ
FXET10AMQ
Part-No.
308134
308157
308136
Rated current output {1}
[A]
4
6
10
Rated current input {2}
[A]
4.2
6.3
10.8
Max. load limit integral of cut-in current {2}
[A
2
s] 0.6
0.7
1,3
Max. leakage current according to the dened networks
of DIN EN 60990 (depending on connected line voltage)
[mA] 2.5 mA (U
typ
230 V)
3.3 mA (U
max
305 V)
2.6 mA (U
typ
230 V)
3.5 mA (U
max
305 V)
3.0 mA (U
typ
230 V)
4.0 mA (U
max
305 V)
Max. line fuse {3}
[A]
16
16
16
Max. heat dissipation approx. {2}
[W]
65
103
187
Rated temperature
[
°
C] 35
40
50
Weight
[kg]
3.4
5.7
6.8
1
Rated current output
current indication name plate @ rated voltage, @ rated temperature
2
At rated voltage, values for different speci
fi
cations on request
3
Max. line fuse on site (line protection fuse) according to EN 60204-1 Classi
fi
cation VDE0113 Part 1
Line voltage*
1 ~ 208...277 V (-10...+10 %), 50/60 Hz
Nominal voltage
230 V
Maximal output voltage
1 ~ 270 V
The PFC (Power Factor Controller) makes it mostly independent of the mains voltage.
Maximal output frequency
150 Hz
Power factor
> 0.9
Switching frequency
16 kHz
Voltage supply
e.g. for sensors
+24 V
±
20 %, I
max
120 mA
Power loss in standby mode (switch
position
“
0
”
)
approx. 2.6 W
Output A1 and A2: 0 - 10 V
Output A3: 0 - 10 V
I
max
per 6 mA (short-circuit-proof)
I
max
per 10 mA (short-circuit-proof)
Max. contact rating of the internal relay 2 A / 250 V AC
Max. permissible ambient temperature
for operation
55
°
C
Min. permissible ambient temperature 0
°
C (if mains voltage is not switched off up to -20
°
C)
Operating Instructions
Fcontrol
–
model series FXET4/6/10AMQ
Function extension and version of software
L-BAL-E079-GB 1706 Index 008
Part.-No.
82/87